2
440 04 2024 01
Specifications are subject to change without notice.
TECHNICAL SUPPORT
Manufacturers Number (Mfr No --
See Rating Plate
) ALL Models
Specifications
*9MPT050F12
*9MPT075F14
*9MPT100J16
*9MPT125L20
General
Gas Type
Nat
Propane
Nat
Propane
Nat
Propane
Nat
Propane
Transformer Size (VA)
T’stat Heat Anticipator
40
.50
Input (Btuh) Std/Alt.
HI Heat
LO Heat
Output (Btuh) Std/Alt.
HI Heat
LO Heat
Temp. Rise (
o
F/
o
C)
HI Heat
LO Heat
50,000
35,000
46,000
32,000
35--65/19--46
25--55/14--30
75,000
53,000
70,000
49,000
40--70/22--38
30--60/17--33
100,000
70,000
93,000
65,000
40--70/22--38
30--60/17--33
125,000
87,500
117,000
82,000
40--70/22--38
30--60/17--33
Electrical (Volts/Hz)
115/60
115/60
115/60
115/60
Rating Plate Amps
11.8
11.8
11.8
14.0
Gas & Ignition
Gas Type
Std. Main Orifices (No/Size)
Gas Valve (Honeywell)
Regulation Type
Manifold Press. HI Heat (in wc/Pa)
LO Heat (in wc/Pa)
Nat.
2/42
VR8205Q
SNAP
3.5/872
1.7/423
Propane
2/54
VR8205Q
SNAP
10.0/2490
4.9/1221
Nat.
3/42
VR8205Q
SNAP
3.5/872
1.7/423
Propane
3/54
VR8205Q
SNAP
10.0/2490
4.9/1221
Nat.
4/42
VR8205Q
SNAP
3.5/872
1.7/423
Propane
4/54
VR8205Q
SNAP
10.0/2490
4.9/1221
Nat.
5/42
VR8205Q
SNAP
3.5/872
1.7/423
Propane
5/54
VR8205Q
SNAP
10.0/2490
4.9/1221
Ignition Type/Series
Hot Surface
Combustion
Flue Outlet Size (Inches)
Std. Outlet Temp
(
o
F/
o
C)
2
<140/60
2
<140/60
3
<140/60
3
<140/60
@ Blower
/
@ Transition Box (HI Heat)
Std. Pressures (in wc/Pa)
5
′
No Elbows
40
′
+5--90
°
DWV Elbows
@ Blower
/
@ Transition Box (LO Heat)
Std. Pressures (in wc/Pa)
5
′
No Elbows
40
′
+5--90
°
DWV Elbows
--1.80
/
--2.60(--448/--647)
--1.30
/
--2.30(--324/--573)
--1.20
/
--1.90(--299/--473)
--1.00
/
--1.80(--249/--448)
--1.80
/
--2.60(--448/--647)
--1.30
/
--2.30(--324/--573)
--1.20
/
--1.90(--299/--473)
--1.00
/
--1.80(--249/--448)
--1.80
/
--2.60(--448/--647)
--1.70
/
--2.50(--423/--623)
--1.20
/
--1.90(--299/--473)
--1.00
/
--1.80(--249/--448)
--1.80
/
--2.60(--448/--647)
--1.70
/
--2.50(--423/--623)
--1.30
/
--2.30(--324/--573)
--1.20
/
--2.20(--299/--548)
Furnace Controls
Furnace Control (Type)
Furnace Control
On
(Timed--secs)
Off
Integrated
30 HI /45 LO
60,100,140,180
Limits & Controls
Rollout Switch (
o
F/
o
C)
Limit Control Setting (
o
F/
o
C)
300/149
260/127
300/149
210/99
300/149
240/116
300/149
180/82
Std. Pressure Sw. (in wc/Pa) Part No
Blower Switch Pressure (Close)
Blower Switch Pressure (Open)
Transition Switch Pressure (Close)
Transition Switch Pressure (Open)
1013515
0.95(237)
0.80(199)
1.70(423)
1.50(374)
1013515
0.95(237)
0.80(199)
1.70(423)
1.50(374)
1013515
0.95(237)
0.80(199)
1.70(423)
1.50(374)
1013166
1.30(324)
1.10(274)
1.80(448)
1.60(398)
High Alt. Pressure Sw. (in wc/Pa)
Part No
Blower Switch Pressure (Close)
Blower Switch Pressure (Open)
Transition Switch Pressure (Close)
Transition Switch Pressure (Open)
1013165
0.70(174)
0.55(137)
1.40(349)
1.20(299)
1013165
0.70(174)
0.55(137)
1.40(349)
1.20(299)
1013165
0.70(174)
0.55(137)
1.40(349)
1.20(299)
1013157
0.85(212)
0.70(174)
1.70(423)
1.50(374)
Blower Data
Blower Size -- D x W inches(mm)
Motor Amps/RPM
Motor Type/H.P.
Cap. Mfd/Volts
Filter Type & Size (qty.) in(mm)
Cool Cap. (Tons) @ .5 in wc (125 Pa)
L, ML, MHi & HI
11 x 8(279 x 203)
10/1050
PSC/
1
/
2
10/370
16x25x1
1.5 thru 3
11 x 10(279 x 254)
10/1050
PSC/
1
/
2
10/370
16x25x1
1.5 thru 3.5
11 x 10(279 x 254)
10/1050
PSC/
1
/
2
10/370
16x25x1
2.5 thru 4
11 x 10(279 x 254)
13/900
PSC/
3
/
4
40/370
16x25x1 (2)
3.5 thru 5
Gas Conversion Kits All Models
Nat to Propane
NAHA002LP (1172959*)
Propane to Nat
NAHA002NG (1172961*)
*Order from Service Parts