2
441 01 1411 04
Specifications are subject to change without notice.
Figure 1
−
Dimensional Drawing
NOTES:
1. Two additional 7/8
−
in. (22 mm) diameter holes are located in the top plate.
2. Minimum return
−
air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.
a. For 800 CFM
−
16
−
in. (406 mm) round or 14 1/2 x 12
−
in. (368 x 305 mm) rectangle.
. . . .
b. For 1200 CFM
−
20
−
in. (508 mm) round or 14 1/2 x 19 1/2
−
in. (368 x 495 mm) rectangle.
. . . .
c. For 1600 CFM
−
22
−
in. (559 mm) round or 14 1/2 x 22 1/16
−
in. (368 x 560mm) rectangle.
. . . .
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a
. . . .
combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
. . . .
Table 1 – Dimensions
FURNACE SIZE
A
B
C
D
VENT
CABINET WIDTH
IN. (MM)
OUTLET WIDTH
IN. (MM)
TOP AND BOTTOM
FLUE COLLAR
IN. (MM)
BOTTOM WIDTH
IN. (MM)
VENT
CONNECTION
SIZE*
IN. (MM)
SHIP WT
(LB / KG)
0451408
14
−
3/16 (360)
12
−
9/16 (319)
9
−
5/16 (237)
12
−
11/16 (322)
4 (102)
104 (47)
0701716
17
−
1/2 (445)
15
−
7/8 (403)
11
−
9/16 (294)
16 (406)
4 (102)
126 (57)
0902116
21 (533)
19
−
3/8 (492)
13
−
5/16 (338)
19
−
1/2 (495)
4 (102)
140 (64)
1102120
21 (533)
19
−
3/8 (492)
13
−
5/16 (338)
19
−
1/2 (495)
4 (102)
152 (69)
1352420
24
−
1/2 (622)
22
−
7/8 (581)
15
−
1/16 (383)
23 (584)
4 (102)*
163 (74)
* 135 size furnaces require a 5 in. or 6 in. (127 or 152 mm) vent. Use a vent adapter between furnace and vent stack.