21
441 01 1411 04
Specifications are subject to change without notice.
ACCESSORIES
1. Electronic Air Cleaner (EAC)
Connect an accessory Electronic Air Cleaner (if used)
using 1/4
−
in female quick connect terminals to the two
male 1/4
−
in quick
−
connect terminals on the control
board marked EAC 1 AMP and NEUTRAL. The termin-
als are rated for 115 VAC, 1.0 amps maximum and are
energized during blower motor operation. (See
Figure 25)
2. Humidifier (HUM 24VAC)
HUM 24VAC: Connect an accessory 24 VAC, 0.5 amp.
maximum humidifier (if used) to the 1/4
−
In male quick
−
connect HUM 24VAC terminal and C screw terminal on
the control board thermostat strip. The HUM 24VAC
terminal is energized when there is a call for heat (W)
and the gas valve relay GVR is energized. (See
Figure 25 and Figure 55).
NOTE
: A field
−
supplied, 115
−
v control relay connected to
EAC terminals may be added if humidifier operation is
desired during blower operation.
NOTE
: DO NOT connect furnace control HUM 24VAC
terminal to H (humidifier) terminal on humidity sensing
thermostat or similar device. See humidity sensing
thermostat, thermostat, or controller manufacturer’s
instructions for proper connection.
Figure 25
−
Furnace Control
ÏÏÏÏ
ÏÏÏÏ
ÏÏÏÏ
ÏÏÏÏ
TWINNING AND/OR
COMPONENT TEST
TERMINAL
P1
−
LOW VOLTAGE MAIN
HARNESS CONNECTOR
TRANSFORMER 24VAC
CONNECTIONS
EAC TERMINAL
(115 VAC 1.0 AMP MAX.)
COOL
SPARE2
SPARE1
COM/BLUE
115
−
VAC (L2) NEUTRAL
CONNECTIONS
24
−
V THERMOSTAT
TERMINALS
HUMIDIFIER TERMINAL
(24
−
VAC 0.5 AMP MAX)
3
−
AMP FUSE
LED OPERATION &
DIAGNOSTIC LIGHT
24VAC/RED
BLOWER SPEED
SELECTION TERMINALS
BL
−
1
XFMR
COM
HEAT
COOL
FAN
SPARE2
SPARE1
Y1
DHUM
HEAT OFF
−
DELAY
12
0 180
90 150
ÏÏ
ÏÏ
ÏÏ
ÏÏ
ÏÏ
ÏÏ
ÏÏ
ÏÏ
24V MTR T
APS
NEUTRAL
−
L2
115 VAC (L1)
NEUTRAL
CONNECTIONS
L1
IND
P2
−
HOT SURFACE IGNITOR (HSI) &
INDUCER MOTOR (IND) CONNECTOR
HEAT
FAN
HUM
24VAC
EAC
1 AMP
HSI
P2