SERVICE AND TECHNICAL SUPPORT MANUAL
Gas Furnace: (F/G)9MXE
Specifications subject to change without notice.
440 04 4311 08
31
PRODUCT NOMENCLATURE
DIGIT POSITION
1
2
3
4
5
6, 7, 8
9, 10
11, 12
13
14
G
9
M
X
E
060
17
14
A
1
G = Mainline Look 1
F = Mainline Look 2
N = Entry
9 = 90%
−
100%
EFFICIENCY
M = Multiposition
H = Horizontal
U = Upflow
D = Downflow
FEATURE
A = Modulating Variable Speed ECM
V = Variable Speed
X = ECM
S = Single
−
stage
T = Two
−
stage
FEATURE
B = Base AFUE Efficiency
E = Extra AFUE Efficiency
C = Communicating
D = Dual Certified 2
−
pipe or 1
−
pipe
R = 2
−
pipe only
S = Single
−
stage
T = Two
−
stage
N = Standard
L = Low Nox
FEATURE
040 = 40,000 BTU/hr
060 = 60,000 BTU/hr
080 = 80,000 BTU/hr
100 = 100,000 BTU/hr
120 = 120,000 BTU/hr
INPUT HEAT
14 = 14
−
3/16”
17 = 17
−
1/2”
21 = 21”
24 = 24
−
1/2”
CABINET WIDTH
10 = 1000 CFM (max)
14 = 1400 CFM (max)
16 = 1600 CFM (max)
20 = 2000 CFM (max)
22 = 2200 CFM (max)
COOLING AIRFLOW
SALES (MAJOR) REVISION DIGIT
ENGINEERING (MINOR) REVISION DIGIT
Copyright 2013 International Comfort Products