INSTALLATION INSTRUCTIONS
Gas Furnace: N9MSE
440 01 4103 03
13
Specifications subject to change without notice.
Figure 9
Unconverted Factory Configuration as viewed in the Downflow Orientation
A11587LA
Remove relief tube from relief
port on condensate trap.
Remove the screw
that secures the trap
to the collector box and
remove trap.
Loosen clamp on inlet
to vent elbow.
Remove pressure switch tube from
front pressure switch and discard. A
new tube is shipped in the loose parts
bag.
Remove tube from relief port.
Remove middle and bottom
plugs. DO NOT DISCARD.
Representative drawing only, some models may vary in appearance.
Downflow Trap Configuration
A11587LB
Install the two plugs
previously removed
on the open ports
of the collector box.
Connect relief tube
to port on collector
box.
Rotate elbow to
desired position and
tighten clamp to
15 lb.
−
in.
Slide tube in stand
−
offs
to adjust length.
Connect the new pressure switch
tube from Loose Parts bag to
port on front pressure switch.
Route tube through inducer
stand
−
offs to adjust position
of the tube.
Trim excess tube.
Connect pressure switch
tube to port on collector
box.
Attach condensate trap
with screw to collector box.
Connect relief tube to
relief port on condensate
trap.
Align condensate trap
over middle and bottom
ports of collector box.
4
5
Representative drawing only, some models may vary in appearance.