INSTALLATION INSTRUCTIONS
Gas Furnace: N9MSE
440 01 4103 03
15
Specifications subject to change without notice.
Horizontal Right Trap Configuration (CONTINUED)
A11573LB
Attach condensate
trap with screw to
collector box.
Slide relief tube in stand
−
offs
to adjust length.
Vent elbow shown in alternate
orientation. Tighten clamp on
inlet to vent elbow 15 lb.
−
in.
Align trap over middle and
right
−
hand port on collector
box.
NOTE: Remove knockout in
casing before re
−
installing the
condensate trap.
Representative drawing only, some models may vary in appearance.
Install plug on
open port of
collector box
Figure 11
Unconverted Factory Configuration as viewed in the Horizontal Left Orientation
A11574LA
If alternate vent position
is required, loosen clamp
on vent elbow inlet.
Remove relief tube
from port on collector
box.
Remove the screw that secures the
condensate trap to the collector box
and remove trap.
Remove relief tube from
relief port on condensate
trap.
Remove front pressure
switch tube and discard.
A new tube is shipped in
the Loose Parts bag.
Remove middle and right
plug from collector box.
DO NOT DISCARD.
5