Section 7, Plumbing the System
Figure 7-1 Heating Module
All fittings, hose and/or tubing involving the domestic water
component of the Distribution Module, must be approved for use
with domestic water and rated for the domestic water system
pressure
NOTICE
•
All plumbing lines must be run and secured so as to prevent
damage, chafing and kinking
•
Ensure that the coolant flow is adequate through the Oasis™
Heating Module and the system. An indication of inadequate
flow is, when the Oasis™ Heating Module is running and up to
normal operating temperature, the difference between the inlet
and outlet coolant temperature to the Oasis™ Heating Module is
less than 20F.
•
The Distribution Module contains three distribution pumps and
one heat exchanger and is pre-wired and pre-plumbed for ease
of installation.
•
The Heating and Distribution Modules should be filled and flushed
prior to operation to remove any foreign debris.
International Thermal Research
7-3
Summary of Contents for Diesel and AC Heating System for Recreational Vehicles and Yachts
Page 14: ...Section 1 Overview 1 8 The Oasis Heating Module...
Page 20: ...Section 2 Mounting the Oasis Heating Module 2 6 The Oasis Heating Module...
Page 28: ...Section 3 Installing the Exhaust System 3 8 The Oasis Heating Module...
Page 32: ...Section 4 Installing the Fuel System 4 4 The Oasis Heating Module...
Page 41: ......
Page 48: ...Section 7 Plumbing the System 7 6 The Oasis Heating Module...
Page 73: ......
Page 74: ...9...
Page 75: ...6 6 6 6 7K 8 0 7 4 7 4 7 8 9 7 8 9 7 8 9 7 8 9 D B 15C 8 D D H D 13 C 8 B B EC 8 D...
Page 76: ...Section 9 Installing the Distribution Module 9 14 The Oasis Heating Module...