Section 6, Wiring the Electrical System
6-2
The Hurricane
®
Chinook Heating System
Primary
12 pin
Hurricane Chinook
Remote
Operating
Panel
Hurricane Chinook Zone Board
10 pin
Harness 2041-70 (50 feet)
10 pin
10 pin
10 pin
8 pin
8 pin
14 pin
Zone Plug 2045-20
12 pin
9 pin
9 pin
Red
Red
Black
Zone 1 Fan
Zone 2 Fan
Zone 3 Fan
Zone 4 Fan
Zone 5 Fan
Summer Loop
Heat Loop 1
Heat Loop 2
Engine Preheat
Power
Zone 1 Thermostat
Domestic Water
Zone 2 Thermostat
Zone 3 Thermostat
Zone 4 Thermostat
Zone 5 Thermostat
AC Box
110 VAC
Ground
Green
White
Black
White
Black
Black
110 VAC
Battery
_
+
Master
Disconnect
25A
Fuse
20A Fuse
Battery
_
+
Cabin
Fans
Thermostats
Thermostat 1 (White)
Thermostat 2 (Yellow)
Thermostat 3 (Pink)
Thermostat 4 (Tan)
Thermostat 5 (Purple)
Bypass Switch
9 pin
9 pin
1 Amp
Fused From
Bve
Yellow
Black
Red
Engine Pre-heat
Orange
Orange
To aquastat
mounted on
Engine Heat
Exchanger or
other heater
source
Figure 6-1: System Wiring
6.2
Hurricane
®
Chinook 12 VDC
The following apply to the 12 VDC connections of the Hurricane
®
Chinook:
•
There is one paired set of 12 VDC electrical connections on the
top left of the Hurricane
®
Chinook
.
They consist of the primary
DC positive (red) and negative (black) connection and are 12
gauge stranded copper wires.