Section 8, Operating the Hurricane
®
Chinook Heating System
8-18
The Hurricane
®
Chinook Heating System
AC immersion elements do not activate
•
Primary Electric Element wires on Hurricane
®
Chinook
connected to 120 VAC power?
•
AC switch on Remote Operating Panel placed in the one or
two element position? AC Heat LED is lit on Remote
Operating Panel?
•
AC immersion elements circuit breakers tripped?
Burner Starts but Flame Faults
•
Fuel nozzle plugged or dirty?
•
Fuel supply present and adequate?
•
Air-intake or exhaust not blocked or obstructed?
•
Air in fuel line (white smoke from exhaust or popping
sound from exhaust)?
•
Fuel filter (external) dirty?
•
Restrict the fuel return line with needle valve or pinch off
completely.
Burner Starts but Zone Faults
•
Power LED on Zone Control Board glowing green?
•
Component matched LED pairings all glowing green on the
Zone Control Board?
•
Fuse blown for one of the pumps or cabin fans on the Zone
Control Board?