7-2
The Oasis
®
Chinook Heating System
7.2 Coolant Plumbing Installation
The plumbing installation should consider the following:
·
The Oasis
®
Chinook has an overflow fitting located on the top of
the unit. Ensure a four (4) quart minimum overflow bottle is
attached to the overflow fitting. The connection point should be
from the bottom of the overflow bottle.
·
The supply and return coolant plumbing connections are on the
top of the Oasis
®
Chinook Heating System. The supply fitting is a
1/2" NPT (female) bulkhead fitting, and the return fitting is a
1/2" NPT (male) fittings. The supply coolant output from the
Oasis
®
Chinook is labeled "Heating Loop 1 Supply". The return
coolant input to the Oasis
®
Chinook is a connection labeled
"Heating Loop 1 Return". Ensure proper direction of flow. Refer
to Figure 7-1: Oasis
®
Chinook Overview for the location of the
fittings.
·
One 1/2" NPT (male) to 3/4" hose barb fitting must be fitted into
the Oasis
®
Chinook coolant supply connection. One 1/2" NPT
(female) to 3/4" hose barb fitting must be fitted into the Oasis
®
Chinook coolant return connection. All connections must be
tightened to a leak free condition using an appropriate thread
sealant.
·
Hose and/or tubing used to connect to the Oasis
®
Chinook
supply and return connections must be heavy duty heater hose,
minimum 3/4” I.D, or 5/8” PEX.
All fittings (except the Heat Loop return fitting) on the Oasis
®
Chinook require two wrenches when tightening. One wrench must
be placed on the bulkhead fitting and held in place to prevent this
fitting from being overstressed. The other wrench can be used to
tighten the matching half of the fitting onto it. Failure to follow this
procedure will damage the Oasis
®
Chinook and the fittings.
Do not operate the Oasis
®
Chinook Heating System until a proper
water/anti-freeze solution has been added to the Oasis
®
Chinook
and the heating system and all trapped air has been bled. An
inadequate mixture may cause system circulation problems and
potential Oasis
®
Chinook Heating System damage and/or personal
injury. Use only a non-toxic, propylene glycol based coolant with
additives recognized as safe “GRAS” by the FDA. Refer to the anti-
freeze manufacturer recommendations for instructions for your
application.
NOTICE
! DANGER