Section 8, Operating the Oasis
®
Chinook Heating System
International Thermal Research
8-11
8.10 Functions of the Oasis
®
Chinook
Control Panel
·
The Oasis
®
Chinook Control Panel (Figure 8-2) contains three
push buttons: Power ON/OFF, Bypass, and Reset. In addition,
it contains nine LED’s indicating Power, AC Heat, Compressor,
Fuel Pump, Combustion Fan, Igniter, Flame Out, Voltage Fault
and Low Water.
Power Button
·
The power button turns ON/OFF the power to the control
board. The Power LED (green) turns ON when the power to
the control board is ON.
Bypass Button
·
The bypass button is for authorized service personnel
only.
Reset Button
·
The reset button when pressed resets the control board.
Power LED (Green)
·
The power LED (green) turns ON when the power to the
control board is ON. The LED flashes when the Oasis
®
Chinook
is in Bypass mode (authorized service personnel only).
AC Heat LED (Green)
·
The AC Heat LED (Green) turns ON when 120VAC is
connected to the unit and the system has not yet reached the
set point operating temperature.
Compressor, Fuel Pump, Combustion Fan, Igniter (Green)
·
The compressor, fuel pump, combustion fan, and igniter LED’s
(Green) turn ON when the component is ON, and will flash if
the component is electrically open or shorted.
Flame Out (Red)
·
The Flame Out LED (Red) turns ON when a flame fault has
been detected.