Section 8, Operating the Oasis
®
Chinook Heating System
8-14
The Oasis
®
Chinook Heating System
Potable Water LED (Green)
·
The potable water LED turns ON when there is a call for
potable hot water.
Zone 1, 2, 3, 4, 5 Fans, Summer Loop, Heat Loop 1, Heat
Loop 2, Engine Pre-heat Pump Paired LED’s (Red/Green)
·
The nine paired LED’s indicate the functionality of the
corresponding devices. The green LED will turn ON when the
device is operating normally. The red LED turns ON if a fuse
has been blown.
8.12 Potable Water and Space Heating
Priority
·
By default, the Zone Control Board is shipped with the
heating priority set for potable hot water. This means that
when there is a call for potable hot water, the space
heating will shut down so all of the available heat can be
directed to the potable hot water circuit. This is done to
support a high flow rate potable hot water demand.
·
If the user wishes to have potable water and space heating
function at the same time, with the understanding that the
potable hot water performance will drop, then a "Priority"
jumper located towards the top left of the Zone Control
Board can be set (Figure 8-5).