Interroll Module belt conveyor SH 1100
Installation
26
Version 1.0 (06/2022) en
Translation of original operating instructions
Installing the photo cell and reflector
The photo cell and reflector are each delivered as a complete unit:
• The photo cell is in the photo cell housing.
• The reflective tape is affixed to the reflector.
Photo cell and reflector can be installed along the C-profile of the side frame. The flexible
universal support enables adjusting the sensors with respect to height and distance and correctly
align them to each other.
DANGER
Danger to life from electrocution and crushing
Installation and maintenance tasks on 400-V conveyor systems while they are in operation can
cause life-threatening electrocution and serious crushing.
4
Power down the entire conveyor module and ensure that it cannot be started accidentally.
Fasten screws with a tightening torque of 19 Nm.
Photo cell and reflector must be installed exactly facing each other: