1

Application Note 1657

Author: Xiaoying Shi

ISL76683 Light-to-Digital Output Sensor Evaluation 

Hardware/Software User Guide

Description

The ISL76683EVAL1Z evaluation board is an RoHS compliant 
evaluation board designed for exploring the operation of the 
ISL76683 light-to-digital output sensor. The evaluation board is 
an easy-to-use platform for testing most of the specifications 
and functionalities described in the 

ISL76683 datasheet

Evaluation Package

• Demo Board (Evaluation Board ISL76683EVAL1Z and USB 

Board ISLUSBCEVAL1Z, REV A), populated with all required 
components

• USB  2.0  Cable
• Evaluation Software (see

 “Tools and Support”

 on

 ISL76683 

device information page

)

• AN1657: “ISL76683 Light-to-Digital Output Sensor 

Evaluation Hardware/Software User Guide” (see 

“Technical 

Documentation”

 on

 ISL76683 device information page

)

System Requirements

• Windows 98/NT/2000/XP
• USB  Port

Hardware Setup

The PC and printed circuit board (PCB) should not be 
connected via the USB until after the evaluation software has 
been installed satisfactorily (see “Software Setup” on page 2).
To set up the hardware:

1. Connect the USB 2.0 cable first to the PC and then to the 

evaluation board. The USB cable is the only connector 
needed.

2. If a dialog appears asking about installing software for 

new-found hardware, click “Yes, this time only”.

The jumpers on the printed circuit board (PCB) are as shown in 
Table 1.

TABLE 1. JUMPERS ON PCB

JUMPER

DESCRIPTION

J500K

Rext = 500

k

Ω

J100K

Rext = 100

k

Ω 

(Default)

J50K

Rext = 50

k

Ω

VDD to 3.3V

Connect 3.3V rail to VDD

CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures.

Copyright Intersil Americas Inc. 2011. All Rights Reserved.

1-888-INTERSIL or 1-888-468-3774

|

Intersil (and design) is a trademark owned by Intersil Corporation or one of its subsidiaries.

All other trademarks mentioned are the property of their respective owners.

August 12, 2011
AN1657.0

Summary of Contents for ISL76683

Page 1: ...s 98 NT 2000 XP USB Port Hardware Setup The PC and printed circuit board PCB should not be connected via the USB until after the evaluation software has been installed satisfactorily see Software Setup on page 2 To set up the hardware 1 Connect the USB 2 0 cable first to the PC and then to the evaluation board The USB cable is the only connector needed 2 If a dialog appears asking about installing...

Page 2: ...ntroller board ISLUSBCEVAL1Z REV A The firmware allows the evaluation software to communicate with the ISL76683 evaluation board through a PC operating on Windows 98 NT 2000 XP Installing the Software Download and run Intersil_ALS_ISL76683_Installer_V100 exe The dialog shown in Figure 2 appears Follow the instructions on each screen for installing the software The PC and PCB should not be connecte...

Page 3: ...76683 Intersil_ALS_ISL76683 2 Double click the program name The Intersil Light Sensor Demo window shown in Figure 3 appears 3 In the Device Select dropdown menu select ISL76683 4 The ISL76683 Light Sensor Evaluation Software window shown in Figure 4 opens This window is the main interface for demonstrating the capabilities of ISL76683 FIGURE 3 SOFTWARE STARTUP FIGURE 4 ISL76683 LIGHT SENSOR EVALUA...

Page 4: ... put the ISL76683 into power down mode MEASUREMENT MODE SELECTION The ISL76683 contains two photodiodes Diode 1 is sensitive to both visible and infrared light while Diode 2 is sensitive mostly to infrared light Measurement Mode 1 is Diode 1 only and Measurement Mode 2 is Diode 2 only Measurement Mode 3 is a sequential Mode 1 and Mode 2 with an internal subtract function Diode 1 Diode 2 You can se...

Page 5: ...n the ISL76683EVAL1Z evaluation board or you can set it to be polled automatically To poll it manually click Sample External Int Pin To poll it automatically click the Poll Interrupt check box to select it With interrupt limits set you can begin collecting data Data is collected within the upper and lower limits you selected In the Interrupt Control dialog in the Interrupt Monitor area black boxes...

Page 6: ...ding field displays the value of the ADC output coming out of the sensor in accordance with the mode that is engaged Click Stop Data Acquisition to stop data sampling Click Exit to close the entire program In the Scale Max text box enter a maximum value for the scale vertical axis and click Manual Re Scale to re set Click Automatic Re Scale to re scale the vertical axis to an appropriate field of ...

Reviews: