26
AN1507.0
September 11, 2009
--------------------------------------------------------------------------------------
# Configuration file for ZL6100EVAL2Z-Ch2
#Erase default and user stores
RESTORE_FACTORY
STORE_DEFAULT_ALL
STORE_USER_ALL
RESTORE_DEFAULT_ALL
MFR_ID
Zilker_Labs
MFR_MODEL
ZL6100EVAL2ZR2
MFR_REVISION
Cfg Rev 1.1
MFR_LOCATION
Austin_TX
MFR_DATE
08_27_09
MFR_SERIAL
ch2
VOUT_COMMAND
1.50
VOUT_DROOP
0.0
VOUT_UV_FauLT_LIMIT
1.275
VOUT_UV_FAULT_RESPONSE
0x80
VOUT_OV_FauLT_LIMIT
1.80
VOUT_OV_FAULT_RESPONSE
0x80
OVUV_CONFIG
0x80
IOUT_SCALE
1.16
IOUT_CAL_OFFSET
-0.25
IOUT_OC_FAULT_LIMIT
45.0
IOUT_AVG_OC_FAULT_LIMIT
38.0
IOUT_UC_FAULT_LIMIT
-15.0
IOUT_AVG_UC_FAULT_LIMIT
-12.0
MFR_IOUT_OC_FAULT_RESPONSE
0xBF
MFR_IOUT_UC_FAULT_RESPONSE
0xBF
VIN_OV_FAULT_LIMIT 14.0
VIN_OV_WARN_LIMIT 13.5
VIN_OV_FAULT_RESPONSE 0x80
VIN_UV_WARN_LIMIT 4.641
VIN_UV_FAULT_LIMIT 4.50
VIN_UV_FAULT_RESPONSE 0x80
OT_FAULT_RESPONSE
0xBF
UT_FAULT_RESPONSE
0xBF
POWER_GOOD_ON
1.35
POWER_GOOD_DELAY
10
TON_DELAY
20
TON_RISE
5
TOFF_DELAY
20
TOFF_FALL
5
DEADTIME
0x3838
DEADTIME_CONFIG
0x0606
MAX_DUTY
96
INDUCTOR
0.56
FREQUENCY_SWITCH
300 # kHz
# CompZL Taps for G=37,
Q=0.25,
f=3.5kHz,
fsw=300kHz, Vi=12,
Vo=1.5
PID_TAPS
A=15207.50, B=-26479.50, C=11342.75 # dIo=15-22.5A @ 2.5A/us, dVo=+/-3%
Application Note 1507