5 aPParaTus Pre-use check
1.
Switch off positive pressure, see section 3.
2.
Open the cylinder valve fully.
3.
With the cylinder valve still open and the positive pressure turned off, read the
shoulder mounted pressure gauge.
nOTe!
THE CYLIndER VALVE PRESSURE GAUGE And THE SHOULdER MOUnTEd PRESSURE GAUGE MUST REAd
FULL PRIOR TO USE. AIR CYLIndERS OF ALL SCBA SHALL BE MAInTAInEd AT nOT LESS THAn 90 PERCEnT OF
THE RATEd PRESSURE STAMPEd On THE CYLIndER.
4.
Close the cylinder valve. The needle of the shoulder mounted pressure gauge
should not move during one minute: If it does - indicating leakage - repairs should
be made by an authorized service personnel and the test repeated.
5.
With the cylinder closed, open the by-pass valve slightly in order to allow the air
to slowly evacuate. Read the pressure gauge when the audible alarm starts to
sound. The pressure gauge should read ¼ full. For the 90USA or 90USA-S 4500
psi cylinder pressure versions, the alarm should sound at approximately 1090
psi. For the 90USA or 90USA-S 2216 psi cylinder pressure versions, the alarm
should sound at approximately 580 psi.
.
When the alarm sounds, turn the by-pass valve to the “OFF” position.
.
depressurize the system by turning on the positive pressure, see section 3.