17
7
DURING USE
DIGITAL DISPLAY
Optional tally
Digital display
with yellow and
red backlight
Panic Button
Red and yellow LED
Backlight /
Scroll button
Fig.
7-A
When the unit is in Run mode with the ADSU/PASS activated (see section 9), the
yellow LED flashes.
During use, the Digital Display can show three different values:
1.
Cylinder pressure
in Bar or PSI
2.
Calculated remaining time
in Minutes
3
.
Absorbed temperature
in Celsius or Fahrenheit
4.
Cylinder pressure graph
in quarters
Depending on the configuration, the display can show one, two, three or all four of
these values. Furthermore, either of these four values can be shown as the default,
second third and fourth priority value.
Pressing the backlight button (Fig. 7-A) activates the backlight of the display for four
seconds. Pressing the backlight button once more while the backlight is lit toggles to
the next value according to configured priorities.
If only one value is shown, there is no toggle function and the backlight button works
as a backlight only.
Pressing the backlight button repeatedly toggles between values. When the backlight
is switched off after four seconds the display will always show the default value.
During use, the remaining air time is calculated based on the previous air
consumption. Since the value is calculated, the displayed time can be both shorter
or longer than the actual remaining time, depending on the previous and future work
load and rate of breathing.