20
3.
When removing the Tally key the red light goes out and the yellow continues. The
4.
Within approximately 20 seconds the HUD and BAC will link. The BAC beeps, the
Digital display reads “HUD CONNECTED” and all six LEDs in the HUD flash two times.
WARNING!
IF NOT ALL LEDS ON THE HUD ARE LIT IT MUST BE IMMEDIATELY BE REMOVED FROM SERVICE.
5.
Press and hold the black button on the Digital display until it switches off.
CHECK HUD LINK
The HUD link can be checked to ensure that the HUD is linked to the correct apparatus.
To check the HUD link, hold the backlight button for two seconds, release it for one
second and then hold it again for two seconds. After the Backlight button has been
released, the two LED lights on the righ hand side of the HUD will start to flash if it is
linked to the apparatus.
NOTE:
ONLY ONE USER CAN CHECK THE HUD LINK AT THE TIME. IF SEVERAL USERS TEST THE HUD LINK AT ONCE IT WILL
BE IMPOSSILBLE TO TELL IF THE HUD IS LINKED TO THE CORRECT APPARATUS OR NOT.
BREATHING APPARATUS COMPUTER (BAC)
The BAC is measuring the pressure and supplying the information to the Digital Display
and HUD. It logs all usage data which can be accessed with a PC interface (optional).
During Run mode, the main LED flashes yellow as a position light.
In addition to the main LED, there are two yellow LEDs for added visibility.
8 CYLINDER PRESSURE WARNINGS
LOW AIR WARNING
Default value is set to 55 +/- 5 bar. It can be configured to a higher pressure (up to
75 bar).
LOW AIR WARNING INDICATION
HUD flashes the red LED or according to configured settings (if fitted with HUD)
BAC emits a warning sound
Main LED of the BAC flashes red
Display LED flashes red
MUTABLE LOW AIR WARNING (OPTIONAL)
Mute the low air warning for one minute by pressing the backlight button (section 8)