10 CLEAN AND DISINFECT
Clean, disinfect and dry parts as necessary after use.
Recommended cleaning and disinfecting agents:
Cleaning:
- BA Cleaner
- BA Manual Cleaner
- Curacid PSA Rinse
Disinfecting:
- Curacid PSA Rapid
- Curacid PSA Ultra
FACE MASK AND EXHALATION VALVE
1. Disconnect the breathing valve from the face mask.
2. Wash the face mask manually
in warm cleaning fluid (maximum 55° C).
3. Rinse the parts in clean water.
4. Disinfect the face mask and the exhalation valve assembly. Follow the instructions
supplied with the disinfectant.
5. Rinse the face mask and the exhalation valve assembly thoroughly with clean
water.
6. Shake the mask to remove excess water and dry the mask and the exhalation
valve assembly.
BREATHING VALVE
1. Mount parking plug, 33438-51, on the breathing valve.
2. With breathing hose attached to the breathing valve, pressurize the breathing
valve and wash it manually in warm cleaning fluid (maximum 55° C) with a
brush or sponge.
3.
Rinse the breathing valve in clean water (maximum 60° C).
4. Depressurize and disconnect the breathing valve from the pressure source.
5. Remove the parking plug 33438-51.
6. Dry breathing valve.
11 STORAGE
Store in a cool, dry and dust-free environment. Protect against direct sunlight, UV
radiation and direct heat.
12 SERVICE AND TESTING SCHEDULE
Service and testing must as a minimum be carried out according to Interspiro’s
Service and Testing Schedule, or according to local requirements. Visit www.
interspiro.com for latest version.