Illustration 2: 

Installation example BLOCKTHERM with TAE

and clearance

Additional  installation  material,  such  as  rails  or  panels
and also junction boxes, are not included in the standard
scope of delivery (see Installation accessories) and must
be ordered additionally.

7

Connection

 INFO

The device may only be connected up and secured by a
trained person, taking into account the "rated voltage"
and "rated current" specified on the nameplate.

Where  operating  voltage  =  measured  voltage  (rated
voltage),  then  the  heater  is  at  its  rated  output.  Mains
voltage fluctuations up to 10 % are then permissible.

For  protection  against  short  circuit  and  line  protection
you can use circuit breakers up to 10 A.

Additional  equipotential  bonding  is  required.  The  ter-
minal  block  designated  for  this  purpose  has  the  ground
sign.

In  a  TT  or  TN  system,  a  residual  current  device  (RCD)
must  be  used  where  the  measured  triggering  residual
current  does  not  exceed  100  mA.  Residual  current
devices with a measured triggering residual current of 30
mA are preferable. In an IT system, an insulation monit-

oring  device  needs  to  be  used  which  switches  off  the
supply as soon as the insulation resistance is no greater
than 50 Ω per Volt of the rated voltage (refer also to DIN
EN 60079-14:2008; section 7.4).

ATTENTION:

Never remove the

adapter/ cable gland!

Illustration 3: 

Example heater with KLE connection

 CAUTION

NOTICE: Do not remove adapter/ cable connec-
tion to connect up the heater!

This would cause irreversible damage to the heater and
this would mean that the explosion protection can no
longer be warranted.

The illustration may deviate from the heater.