Operating Instructions CP VARITHERM DBPA
HOM146742411Ien-6
Page 5 / 8
INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany ·
+49 9445 9532-0 · info@intertec.info
Profile type "P" Height x
Width x Depth
213 x 220 x 80
mm
Profile type "P" Height x
Width x Depth
213 x 220 x 60
mm
Profile type "P" Height x
Width x Depth
213 x 220 x 40
mm
INFO
You will find the precise technical data for your
instrument on the label.
Rated output
Rated voltage/Operating voltage
Thermostat
Temperature class
Illustration 1:
Example: CP VARITHERM DBPA 300 T3 60
TS10 label
8
Installation
NOTICE
Carefully remove
When removing from the packaging and during
transport, the connection line must not be stressed or
bent.
For free convection, the heater needs to be installed with
ribs standing vertically. The minimum distances to the
floor and to devices above it must be complied with. The
label needs to remain legible.
If an additional TAE thermostat is switched in series,
then it can be attached to the surface of the heater
(thermal coupling). The minimum distance also needs to
be adhered to here. Refer to the following drawing.
To ensure operational safety, the heater must operate
under temperature conditions which will NOT exceed the
trigger temperature of the limiter.
The operating temperatures must be adhered to.
The connection cable must be permanently installed up
to the inlet into the on-site junction box, taking the
permissible bending radius = 5 x outer diameter into
consideration.
In the dust Ex area, the applicable requirements of
ABNT NBR IEC 60079-14 must be complied with.
Illustration 2:
Installation example horizontal VARITHERM with
TAE or TS and clearance
Illustration 3:
Installation example vertical VARITHERM with
TAE or TS with clearance
Additional installation material, such as rails or panels
and also junction boxes, are not included in the standard
scope of delivery (see
)
and must be ordered additionally.