Operating Instructions SL HORIZOTHERM DNA
Page 4 / 8
HOM1435401867Ien-2
INTERTEC-Hess GmbH · Raffineriestr. 8 · 93333 Neustadt/Donau · Germany ·
+49 9445 9532-0 · info@intertec.info
CAUTION
Risk of burns from a hot surface
Attainable highest temperatures:
- Max. 160°C with T3 heating systems
- Max. 100°C with T4 heating systems
- Max. 70°C with T5 heating systems
- Max. 50°C with T6 heating systems
Do not touch device during operation! Before working on
the device, allow it to cool down first.
5
Installation accessories
The following are included in the scope of delivery:
Piece
Description
1
Heating unit
1
Angle bracket made of flat steel
1
Packet of screws containing the following:
2
M 6x12 hexagon bolts
1
T-head bolt type 28/15, M 6x15
1
Washer shape A 6.4
2
Lock washers shape J 6.4
If one of the components listed here is not included in
the scope of delivery, then please contact the manufac-
turer.
6
Technical Data
Protection class
IP66/IP68 1bar/30min
Rated voltage
max. 265 V AC
Permitted operating voltage
max. 275 V AC
Rated current (in compli-
ance with VDE 0298)
max. 10 A
Ambient temperature
- 60 to + 60°C
Max. permitted operating
temperature
- 60 to + 180°C
Switching capacity of fault
alarm (AM)
10 A / 275 V AC
Connecting cable
Silicone hose cable,
notch- and oil resistant, 3
x 1,5 mm²
Connecting cable AM
Silicone hose cable,
notch- and oil resistant, 5
x 1,0 mm² Ø8,5 mm
Material
Seawater-proof alu-
minium, black anodized
Mean Time Before Failure
50.000 h
Storage temperature
- 60 to + 80°C
Profile type "N" Height x
Width x Depth
152 x 155 x 40
mm
Profile type "N" Length x
Width x Height
155 x 152 x 40
mm
INFO
You will find the precise technical data for your in-
strument on the label. You will find information on
the heating output on the data sheet.
Temperature class
Rated voltage/Operating voltage
Rated output
Thermostat
Illustration 1:
Example: SL HORIZOTHERM DNA 100 T3 40
TS30 label
7
Installation
NOTICE
Carefully remove
When removing from the packaging and during trans-
port, the connection line must not be stressed or bent.
Free convection may not be impeded. You will find the
minimum distances and installation position in the follow-
ing figure.
The label needs to remain legible.
Please make sure that the absolute heat transfer coeffi-
cient of the surrounding housing is not smaller than 0.5
W/K.
To ensure operational safety, the heater must operate
under temperature conditions which will NOT exceed the
trigger temperature of the limiter.
The operating temperatures must be adhered to.