DISH FIREBOWL | Owner and Installation Manual

APPROVED FLEXIBLE GAS HOSE

A.G.A DESIGN-CERTIFIED MANUAL 

SHUTOFF VALVE WITH 1/8” NPT TAP

3” MINIMUM

CAP PIPE NIPPLE TEE JOINT

FROM GAS METER (5” W.C. 

TO 10.5” W.C. PRESSURE)

SEDIMENT TRAP

INSTALLATION REQUIREMENTS

Installation must include a manual shutoff valve, union, 

and plugged 1/8” NPT tap. Locate NPT tap within reach 

for test gauge hook up. NPT tap must be upstream from 

the appliance.

Apply pipe joint sealant lightly to male threads. This will 

prevent excess sealant from going into pipe. Excess 

sealant in pipe could result in a clogged burner injector.

Install sediment trap in supply line as shown below. 

Locate sediment trap where it is within reach for cleaning 

and trapped matter is not likely to freeze. 

A sediment trap prevents moisture and contaminants 

from entering the Outdoor Fire Pit controls. If a sediment 

trap is not installed, or is installed incorrectly, the unit may 

not work properly.

CHECKING GAS CONNECTION

       WARNING: Test all gas piping and connections 

for leaks after installing or servicing. Correct all leaks 

immediately.

       WARNING: Never use an open flame to check 

for a leak. Apply a mixture of liquid soap and water 

to all joints. Bubbles forming on joints while the 

gas is running indicate a leak. Correct all leaks at 

immediately.

Test Pressures in Excess Of 1/2 psi (3.5 kPa)

This appliance and its individual shutoff valve must be 

disconnected from the gas supply piping system during 

any pressure testing of that system at test pressures in 

excess of ½ psi (3.5 kPa).

Test Pressures Equal To or Less Than 1/2 psi (3.5 kPa)

This appliance must be isolated from the gas supply 

piping system by closing its individual manual shutoff 

valve during any pressure testing of the gas supply piping 

system at test pressures equal to or less than ½ psi (3.5 

kPa).

CONNECTING TO GAS SUPPLY

 WARNING:

A qualified service person must 

connect the appliance to the gas 

supply. Follow all local codes.

CAUTION: 

Use only new black iron or steel pipe. 

Internally tinned copper tubing may be 

used in certain areas. Use pipe of 1/2” 

diameter or greater to allow proper 

gas volume to Outdoor Fire Pit Burner. 

If pipe is too small, undue loss of 

pressure will occur.

INSTALLATION ITEMS NEEDED:

Before installing the Outdoor

Fire Pit, make sure you have all items 

listed bellow:

•  piping (check local codes)

•  sealant

•  manual shutoff valve

•  adjustable (crescent) wrench or pliers

•  sediment trap

•  tee joints

•  pipe wrench

                 

 

Summary of Contents for CIR-18

Page 1: ... department WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cyllinder not connected for use shall not be stored in the vicinity of this or any other appliance CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you Never use this appliance in an enc...

Page 2: ...FPA 54 or the International Fuel Gas Code 3 Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 4 Do not burn solid fuel in this appliance Do not use this appliance to cook food or to burn paper or other objects 5 Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clo...

Page 3: ...will ensure that the final position of the unit will not be compromised We recommend that gas risers be kept as low to grade as possible and no higher than 3 at their highest points Air gaps may be used to route surface mounted propane hoses ATTENTION Gas line must be installed by a licensed contractor in compliance with local codes FIG 1 PLAN AND VERTICAL SECTION See page 8 of this manual for Gas...

Page 4: ...e mounted propane hose feed it through one of the air gaps 7 6 If the Dish Body does not sit level shim appropriately so that it is level and evenly supported 7 Connect to Natural Gas or Propane Source as per page 8 of this manual 8 Assemble Burner as per instructions on page 7 9 Check for leaks and test burner see page 8 10 Place Topping Ring 3 back into Body 4 Remove Control Knob 6 and stem from...

Page 5: ...L Owner and Installation Manual 3 Topping Ring 5 Control Port 1 Burner Assembly 8 Flex Hose Gas Connection 9 Main Test Point 2 Valve Assembly 6 Control Knob 7 Air drain gap 4 Body FIG 2 DISH EXPLODED VIEW COMPONENTS ...

Page 6: ...6 DISH FIREBOWL Owner and Installation Manual FIG 3 MINIMUM CLEARANCES TO COMBUSTIBLES CLEARANCE TO COMBUSTIBLES 72 12 ...

Page 7: ... Turn OFF the appliance and let it cool before proceeding to the next step 7 Place and evenly distribute remaining lava rock on top of burner and topping ring Keep the lighting port open and free of media WARNING Failure to position parts in accordance with these diagrams and instructions and or failure to use parts specifically approved for use with this appliance may result in property damage or...

Page 8: ...ame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming on joints while the gas is running indicate a leak Correct all leaks at immediately Test Pressures in Excess Of 1 2 psi 3 5 kPa This appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ...

Page 9: ...Specifications Minimum Clearances to Combustible Materials MODEL MAX INPUT BTU Hr INLET PRESSURE MIN INLET PRESSURE MAX MANIFOLD PRESSURE ORIFICE SIZE BURNER PORTS PORT SIZE CIR 18 70 000 4 5 W C 10 5 W C 3 5 W C 18 68 1 8 CIR 18P 70 000 11 0 W C 13 0 W C 7 5 W C 37 68 1 8 ABOVE SIDE BELOW 72 18 0 ...

Page 10: ...e can result in injury or property damage For assistance or additional information consult a qualified installer service agency or the gas supplier Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this appliance INITIAL LIGHTING INSTRUCTIONS 1 Purge air from the supply line as follows Open the main shutoff valve Unscrew the main pressure test point Leave the inl...

Page 11: ... gas control knob and light the pilot immediately by applying a flame to the lighting port Hold the knob down for one full minute after lighting the pilot 4 When the gas control knob is released the pilot flame should continue to burn if the pilot goes out repeat the above steps 5 Rotate the gas control knob from PILOT to ON position full counterclockwise position to supply full flow to main burne...

Page 12: ...ure the burner porting and burner air openings are free of obstructions at all times Inspect area around the burner Remove any lint or foreign material with a brush or vacuum cleaner The burner must be replaced prior to the appliance being put into operation if it evident that the burner is damaged PILOT FLAME The flames from the pilot should be visually checked as soon as the unit is installed an...

Page 13: ...flame passage 3 Remove any foreign items from the flame pattern and or check for proper orifice sizing Burner is excessively noisy Note The movement and combustion of gas will create low unavoidable levels of noise 1 Passage of air gas across irregular surfaces 2 Excessive gas pressure on natural gas units 1 Relieve any tight bends or kinks in gas supply line 2 Check reset gas regulator pressure G...

Page 14: ...nce page 12 or replace pilot assembly Burner does not light after pilot is lit 1 Burner orifice is clogged 2 Inlet gas pressure is too low 3 Burner orifice diameter is too small 4 Flame sensor lead loose or disconnected 1 Clean burner orifice 2 Contact local gas or propane supplier 3 Replace burner orifice 4 Reconnect or tighten lead Delayed burner ignition 1 Pilot flame needs adjusting 1 Adjust p...

Page 15: ...Orifice Lock Nut 3 8 FPT x 1 2 MFL Connector 3 8 MPT x 1 2 MFL Connector 3 8 Nipple Close 1 2 Flex Connector 10 1 1 1 1 1 1 2 1 2 RBP018 PAN025 VNG017 O33018 LN111C CO488C CO468C CO112C FC4810 RBP018 PAN025 VLP017 O33037 LN111C CO488C CO468C CO112C FC4810 KEY DESCRIPTION QTY CIR 18 CIR 18P 10 10b 11 12 13 14 15 16 Main Valve Control Knob Pilot Assembly Pilot Shield Regulator Valve Bracket Set 2 pi...

Page 16: ...16 DISH FIREBOWL Owner and Installation Manual ILLUSTRATED PARTS LIST cont d 10 11 12 6 8 3 5 13 14 4 9 15 16 ...

Page 17: ...17 DISH FIREBOWL Owner and Installation Manual NOTES ...

Page 18: ... installation instructions The Limited Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 fire pit burner assembly damaged by accident neglect misuse abuse alterations negligence of others including the installation thereof by unqualified installers 2 the costs of removal r...

Reviews: