Parts List:
Paper Template W601
InterVac Model #RMH220 or RMF220
4 screws with screw caps
Paper template:
2 vacuum bags, Part
CE Terminal block
various pipe fittings
1 wood strip for RMF model
With the InterVac model RM220 you have 2 mounting options:
1 : Recessed mounted in a wall.
2 : Surface mounted against a wall.
Look for a electrical outlet or a 5.5 amp circuit breaker for your power supply line.
:
Attach the paper template to wall or surface a minimum of 100mm above the floor, so that the
exhausting air is not restricted.
Read instructions on paper template.
Place the vacuum cleaner in the cut-out, lower end first, and secure with the four painted
screws.
Install the remote vacuum valve(s). Please note that the standard inlet valve fits a max. 5/8
thick wall. Extensions are available.
the flex-hose the shortest way to the inlet valve.
From the remote vacuum valve route two wires .75mm CE approved (H05V2 rated) minimum 300V,
60 C, (24-volt line) along the flex-hose to the bottom of the vacuum cleaner housings and connect it to
the two
Secure the wires with “ty-wraps” or electric tape to the flex-hose.
nstall 1.5mm H05V2, 300V , 220/240 volt power supply cable (use wires rated for at least 95 C.)
though the 20mm hole. Connect to the terminal block inside housing. Wrap strain relief around
power cable and with a pair of plier insert into the housing hole.
If an electric cord is supplied, plug into a receptacle.
#W600 or W601
# Y08
NOTE:
The
WARNING
Step 1.
Step 2.
Step 3.
Step 4.
Step 7.
.
Step 8.
NOTE: A means of disconnecting the wires must be incorporated in accordance with local wiring
rules and regulations.
st
nd
MODEL RMF220, to be hard wired, FLUSH MOUNTED into a WOOD SURFACE
four mounting holes in the outer corners of the flange of the RMF220 have to be opened up from the
back with a 5mm” drill bit.
Disconnect all electrical power to the wall area before drilling and cutting! Do not drill near studs
where electrical cable may be secured to studs adjacent to receptacles.
yellow wires
The
requires 100mm depth, measured from the front of the wall.
To reach with the vacuum hose as far as possible, install the
(s) in a central location.
The vacuum unit should be mounted as close as possible to the remote valve(s). The shorter the
distance the better the airflow.
Make sure there are no obstruction behind the wall before you start cutting.
Now install the flanged fitting to the vacuum cleaner from the back of the wall with the four #6 X 12mm
screws.
Attach the 50mm flex-hose . Route
Replace the access cover .
vacuum cleaner power unit
remote valve
The ground conductor of the
is not used and should be cut and insulated.
Step 5.
Step 6.
I
power supply cable
4