MODEL RMH220, with electric cord, Surface Mounted Installation
Paper Template W600
Step 1.
Step 2.
Step 3.
NOTE
Step 4.
Step 5.
Step 6.
Step 7.
.
Step 8.
remote valve
To reach with the vacuum hose as far as possible, install the
(s) in a central location.
The vacuum unit should be mounted as close as possible to the remote valve(s). The shorter the
distance the better the airflow.
Look for a electrical outlet or a 5.5 amp circuit breaker for your power supply line if you hard wire.
the unit,
the screws re-tight
NOTE:
I
Tape the paper template to the wall or surface at a minimum of 100mm away from any obstruction
which might block the exhausting air.
Attach the four screws (#8) through the paper template into the wall. Keep the screw heads
about 1/8 from the wall surface.
Attach vacuum cleaner to the four screw heads into the four keyholes in the back of
then slide
unit down into locked position. If vacuum cleaner is loose on
en screw heads.
:
Attach the flanged fitting to the top of the housing with the four #6 X 12mm screws .
Route the 50mm flex-hose the shortest way to the inlet valve.
Install the remote vacuum valve(s) in a central location.
Attach the flex-hose to the ends of the fittings, either with hose clamps or with PVC glue.
From the remote vacuum valve install two wires, .75mm rated H05V2, 300V, 60 C, cable (24-volt line)
along the flex-hose to the bottom of the housing, and connect to the two
Secure the wires
with “ty-wraps” or electric tape to the pipe system.
If an electric cord is not supplied, install a 1.5mm H05V2, 220/240volt power cable (use wires rated for
at least 95 C) through the 20mm hole in the bottom of the housing and connect to the terminal block
inside the unit. Wrap the strain relief around the power cable and with a pair of pliers insert into the
hole.
f unit is to be installed in a small closet or tight area, adequate ventilation should be installed for the exhausting
air. Keep pipes or flex-hose as short as necessary, using as few elbows as possible. Every radius in the piping
system is a restriction and deteriorates the power of the unit.
If the Vacuum unit is mounted on it’s back or in an angle it may slide off the screws heads. To prevent this, attach a
small block with a screw against the top as a stop.
yellow wires
The green ground conductor of the
is not used and should be cut and insulated.
power supply cable
Paper Template:
# W600
Paper Template:
#W601 recessed mounted
Tape template to wall
5
about 6” from floor
Model RMH-220
Model RMF-220