OPERATION
32
System Status
The DCC Pro has a number of protection and monitoring mechanisms built in
to protect the product from application and installation issues as well as faults
that may occur in exceptional circumstances. To assist with troubleshooting any
problems that arise, the DCC Pro can indicate these issues in one of two ways,
via the Charging Device itself or on the Remote Display (if connected).
The Charging Device incorporates the LED Glow Ring, a multi-colour,
multi-function indicator which is illuminated according to the status of the
device. The Glow Ring will reflect a range of conditions as a visual indication to
the operator/installer.
The Remote Display can visually and audibly alert the operator to the same
conditions as indicated by the LED Glow Ring with the advantage, as the name
indicates, of being located away from the Charging Device. These conditions
are detailed in the table below.
*
Use the
button to ‘awaken’ the display for temporary viewing.
NOTE:
For further information on alert conditions (1- 4) please refer to
troubleshooting guide on the following page.
OK
Glow Ring
Colour
Glow Ring
Frequency
Status
Remote Display
Indication
Condition Charger
State
White
Intermittent
(8 seconds)
Stand by
STAND BY
*
Normal
Purple
Intermittent Set-up
TO CONFIG
...
Normal
Blue
Continuous
Boost/CC
DC
or
pv
BOOST
Normal
On
Blue/Green Alternate
Absorption/CV
DC
or
pv
ABSorb
Normal
On
Green
Continuous
Float/CV
DC
or
pv
FLOAT
Normal
On
Yellow
Intermittent High
Voltage
HIgh main
High AUX
high solr
Alert
1
Orange
Intermittent Over
Temperature
OVER TEMP
Alert
2
Red
Continuous
N/A
Device Issue
check dvc
Alert
3
Red
Intermittent
S.O.S.
Reverse
Polarity
Alert
4
DC
or
pv BMS CC
DC
or