background image

 

           

       

 

 

 

                         
 
                                      

 

 

 

 

IntesisBox

®

 BACnet/IP Server – SUNWAYS 

 

Doc. Rev.0 

Installation Manual

 

URL

email

tel

http://www.intesis.com                                         
info@intesis.com 
+34 938047134 
 

    2 / 5

This information is subject to change without notice.

 

 

 
 
 

1.  Separate the fixing clips in the bottom of the box, pushing them to the outside until hear the "click" which 

indicates that now the clips are in position for wall mount, see in the figure below. 

 

 

 
 
 
 
 
 

 

 
 
 
 
 

 

2.  Use the holes of the clips to fix the box in the wall using screws. Use the template below for the wall holes. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
With the clips of the box in their original position, insert first the box in the upper edge of the DIN rail and later insert 
the box in the down part of the rail, using a small screwdriver and following the steps in the figure below. 

 
 
 
 
 
 
 
 
 

Wall mount 

 

Clips in their original position, for DIN rail 
mount 

Clips in position for wall mount 

DIN

 Rail 

Top view of the box 

DIN rail mount 

 

Side view of the box 

Botton view of the box 

100 mm 

IntesisBox

® 

www.intesis.com

 

61 mm 

Ø  3 mm 

Summary of Contents for BACnet/IP Server-SUNWAYS

Page 1: ...ischarge to the unit in environments with static levels above 4 kV precautions should be taken when the device is mounted outside an enclosure When working in an enclosure ex making adjustments setting switches etc typical anti static precautions should be observed before touching the unit Safety Instructions WARNING Follow carefully this safety and installation instructions Improper work may lead...

Page 2: ... 2 Use the holes of the clips to fix the box in the wall using screws Use the template below for the wall holes With the clips of the box in their original position insert first the box in the upper edge of the DIN rail and later insert the box in the down part of the rail using a small screwdriver and following the steps in the figure below Wall mount Clips in their original position for DIN rail...

Page 3: ...tance of 1200 meters maximum 32 device connected and a 120 ohms terminator resistor in each end of the bus IntesisBox comes with an internal bus biasing circuit which incorporates internal bus terminator resistor and thus if you connect IntesisBox in one end of the bus then it is not necessary to install additional 120 ohms resistor in that end BACnet IP connection Connect the cable coming from th...

Page 4: ...ort 1 x Serial EIA485 Plug in screw terminal block 2 poles SELV BACnet IP port 1 x Ethernet 10Base T RJ45 LED indicators 1 x Power 2 x Sunways port activity Tx Rx 2 x Ethernet port link and activity LNK ACT Console port EIA232 DB9 female connector DCE SELV Configuration Via console port 1 Firmware Allows upgrades via console port Operational temperature 0 C to 70 C Operational humidity 5 to 95 non...

Page 5: ...com info intesis com 34 938047134 5 5 This information is subject to change without notice Dimensions External dimensions Free space recommended to install the device with spacing enough for external connections 115 mm 130 mm 100 mm Power Ethernet port 107 mm 105 mm 58 mm Console port Sunways port ...