29
6.5 Blower
Article:
AL-BL30*
AL-BL60*
AL-BL100
AL-BL120
AL-BL200
Blower size:
30 L
60 L
100 L
120 L
200 L
8 Gallons
16 Gallons
26 Gallons
32 Gallons
52 Gallons
Length:
207 mm
(8.2 “)
305 mm
(12 “)
408 mm
(16 “)
408 mm
(16 “)
418 mm
(16.5 “)
Width:
182 mm
(7.2 “)
214 mm
(8.4 “)
210 mm
(8.3 “)
210 mm
(8.3 “)
212 mm
(8.4 “)
Height:
205 mm
(8.1 “)
188 mm
(7.4 “)
232 mm
(9.2 “)
232 mm
(9.2 “)
268 mm
(10.6 “)
Power supply:
230 V AC/50-60Hz, 1 phase
Pressure, working
range up to:
0.11 bar
(1.6 psi)
0.15 bar
(2,2 psi)
0.18 bar
(2.6 psi)
0.2 bar
(2.9 psi)
0.3 bar
(4.4 psi)
Aeration flow:
17–35 L/min
(0.6-1.2 CFM)
20–85 L/min
(0,7-3 CFM)
50–128 L/min
(1.8-4.5 CFM)
75–145 L/min
(2.7-5.1 CFM)
110–280 L/min
(3.9-9.9 CFM)
Power
consumption:
29 W
65 W
100 W
130 W
215 W
Hose connection: Ø 18 mm
(0.7 “)
Ø 18 mm
(0.7 “)
Ø 26 mm
(1.02 “)
Ø 26 mm
(1.02 “)
Ø 26 mm
(1.02 “)
Protection class:
IP54
IP54
IP54
IP54
IP54
Weight incl. wall
bracket:
2.9 kg
(6.4 lbs)
5.0 kg
(11 lbs)
9.4 kg
(20.7 lbs)
9.4 kg
(20.7 lbs)
12.5 kg
(27.6 lbs)
*not usable for NSF applications
The blowers AL-30 up to AL-BL200 are designed for wall mounting. The mounting material is supplied
with the blower.
Summary of Contents for AQUALOOP GW 10800
Page 12: ...11 Fig AQUALOOP System 1200 L day 317 GPD Fig AQUALOOP System 1800 L day 476 GPD...
Page 13: ...12 Fig AQUALOOP System 3600 L day 952GPD Fig AQUALOOP System 5400 L day 1428 GPD...
Page 37: ...36 Fig Electrical connection plan upper pump lower pump...
Page 39: ...38 Fig Control cabinet of multiple membrane station controller...
Page 42: ...41 7 1 3 Expansion membrane station controller Fig Control cabinet of expansion controller...
Page 89: ...88 Designed and provided by INTEWA GmbH or to be separately approved alternative...
Page 90: ...89 INTEWA GmbH Version 1 1 a Subject to technical changes...