Owner’s manual
EN
IMPORTANT SAFETY INSTRUCTIONS
•
When replacing the batteries, use the same number and the same type of
batteries.
•
Do not dispose of batteries in a fire; the battery may explode.
•
Do not open or mutilate the battery or batteries, released electrolyte is harmful to
the skin and eyes.
•
A battery can present a risk of electric shock and high short circuit current. The
following precaution should be observed when working on batteries:
•
Remove watches, rings or other metal objects.
•
Use tools with insulated handles.
•
The socket-outlet shall be installed near the equipment and easily accessible.
•
Attention: hazardous through electric shock. Also, with disconnection of this
unit from the main, hazardous voltage still may be accessible through supply of
battery.
•
The battery supply should be therefore disconnected in the plus and minus pole
through or from the outer enclosure accessible battery fuses when maintenance
or service work inside the UPS is considered.
•
The lead acid battery may cause chemical hazard.
•
The battery presents a risk of electric shock and energy hazard.
•
Batteries will be disposed by the manufacturer or importer. Customers need to
send them back with no charge for disposal.
CAUTION:
•
Incorrect connection to battery (reverse polarity) may cause damage to the
internal protections of this device.
•
AC power mains overvoltage may cause damage to the internal protections
of this device.
SPECIFICATION
Power
400 W
Battery type
12 VDC
Input voltage range
155~270 VAC (+/-7 VAC)
Input frequency
50 Hz
AVR output voltage range
200~250 VAC (+/-7 VAC)
Output voltage (battery mode)
230 VAC (+/-10 VAC)
Output frequency (battery mode)
50 Hz
Transfer time
<10 ms
Battery charging current
max. 6 A
Output wave form (battery mode)
Sine wave
Overload alarm in mains mode
460 +/- 50 W