SAVE THESE INSTRUCTIONS
(341PO) MODEL SF90110-1 SAND FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U
04/01/2021
English
Page 15
OPERATING INSTRUCTIONS
• Risk of electric shock. Connect this product only to a grounding type receptacle protected by a
ground-fault circuit interrupter (GFCI) or residual current device (RCD). Contact a qualified electrician if
you cannot verify that the receptacle is protected by a GFCI/RCD. Use a qualified electrician to install
the GFCI/RCD, which has a maximum rate of 30mA. Do not use a portable residual current device
(PRCD).
• To reduce the risk of electric shock, do not use extension cords, timers, plug adaptors or converter
plugs to connect unit to electric supply; provide a properly located outlet.
• Do not attempt to plug in or unplug this product while standing in water or when your hands are wet.
• Never operate this product above the maximum working pressure stated on the filter tank.
• Always switch off pump before changing the 6-way valve position.
• Operating this product without water flowing through the system can cause a build up of hazardous
pressure which can result in an explosive situation, serious injury, property damage or death.
• Never test this pump with compressed air. Never operate the system with water temperature
above 35° C (95° F).
Valve Position
Function
Water Flow Direction
FILTER
(see drawing 23)
Normal filtration and regular vacuuming
of pool
From pump through filter media to
pool
BACKWASH
(see drawing 24)
Reverses water flow to clean filter
media
From pump through filter media to
valve waste/drain outlet
RINSE
(see drawing 25)
For initial startup cleaning of the sand, and
leveling the sand bed after backwashing
From pump through filter media to
valve waste/drain outlet
WASTE
(see drawing 26)
For vacuuming directly to waste,
lowering pool level or to drain the pool
From pump to valve waste/drain
outlet bypassing the filter media
RECIRCULATE
(see drawing 27)
For circulating water back to pool
without going through the filter media
From pump through valve to
pool bypassing the filter media
CLOSED
(see drawing 28)
Shuts off all flow to filter and pool
“Do not use this setting with pump running”
6-way valve positions and function:
WARNING
23
26
27
28
24
25
Control panel description:
ON / OFF button
LOCK / UNLOCK button
TIMER button
LED Reading
Definition
00
Stand-by mode (start-up / operating cycle finished)
01
Minimum operating hour (1 hour remaining)
02-11
Operating hours (2 – 11 hours remaining)
12
Maximum operating hours (12 hours remaining)
FP
Timer OFF (pump operating continuously)
Power saving mode
.