background image

192

PO

S  AVE  THESE  INSTRUCTIONS

(192PO)  SPA  ENGLISH  7.5” X 10.3”  PANTONE 295U  04/18/2013

English

 SET UP

 (continued)

Setup the spa with at least 2 persons.

1.

    Move the entire package to the selected site. Do not drag the spa tub across the ground as this can  

 

    cause damage and leakage. 

    Open the carton carefully as this carton can be used to store the spa during long term storage or when    

    not in use.

2.

    Lay out all the parts on the ground and make sure all the parts are accounted for

For missing or  

 

    damaged parts contact the appropriate Intex Service Center listed in the separate “Authorized service    

    Centers” sheet.

Safety Sign Card Posting

The Safety Sign card included with the manual shall be posted in an area visible to the users of the spa to 

alert them of the safety rules and warnings. For replacement of the safety sign card, visit our website at 

www.intexcorp.com for additional print copies. Laminate the printed safety sign copy for protection from the 

elements.

Spa Control Unit Assembly

1.

  Connect the control panel 

(3) 

cable plug into the receptacle on top of the spa control base

 (see 

 

drawing 1).

2.

  Screw the control panel bolts 

(4)

 with the provided bolt wrench 

(6)

 to secure the control panel 

 

(see drawing 2).

3.

  Plug the spa control unit into a grounded electrical outlet.

Page 8

Inflation

Inflate the Spa Tub Wall

1. 

Take out the ground cloth 

(19)

 and spread it over the cleared area. Then spread out the 

spa liner

 over   

 

the ground cloth and

 point the drain valve towards a suitable draining area.

2.

  Unscrew the control panel cap 

(5)

 on top of the control panel to reveal the air blower inflation outlet and  

 

connect one end of the inflation hose 

(7) 

to the outlet 

(see drawing 3)

.

3.

  Unscrew the air valve cap to reveal the stem in the up position for inflation. Insert the other end of the    

 

inflation hose 

(7)

 into the valve and turn to the right to lock it in position

 (see drawing 4)

.

7

5

7

1

2

3

4

1

3

4

6

2

Summary of Contents for PureSpa SSP-10

Page 1: ...at fine retailers or visit our website Due to a policy of continuous product improvement Intex reserves the right to change specifications and appearance which may result in updates to the instruction manual without notice For illustrative purposes only IMPORTANT DO NOT RETURN PRODUCT TO STORE To purchase parts and accessories or to obtain non technical assistance visit www intexcorp com For techn...

Page 2: ...IONS 192PO SPA ENGLISH 7 5 X 10 3 PANTONE 295U 04 18 2013 English Page 2 Warning 3 4 Parts 5 6 Set up 7 10 Operation 11 LED Code Chart 12 Maintenance and Chemicals 13 15 Storage 15 Troubleshooting 15 Warranty 16 TABLE OF CONTENTS ...

Page 3: ...is purpose Risk of Electric Shock Do not permit any electric appliance such as a light telephone radio or television within 5 feet 1 5 m of a spa or hot tub Risk of Electric Shock Do not use the spa when it is raining thundering or lightning A wire connector is provided on this unit to connect a minimum 8 AWG 8 4 mm2 solid copper conductor between this unit and any metal equipment metal enclosures...

Page 4: ...adaptors or converter plugs to connect unit to electrical supply provide a properly located outlet Do not attempt to plug in or unplug this product while standing in water or when your hands are wet Do not leave the spa empty for extended period of time Do not expose the spa under direct sunshine Adequate drainage system must be provided around the spa to deal with overflow water Do not allow the ...

Page 5: ...3 English Page 5 PARTS Before assembling your product please take a few minutes to check the contents and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary Not to scale 8 9 10 11 18 17 19 20 21 23 22 1 2 6 7 3 4 5 12 13 14 15 16 24 ...

Page 6: ...R 1 11713 12 FILTER CARTRIDGE HOUSING 2 11691 13 FILTER CARTRIDGE 2 11692 14 FILTER CARTRIDGE HOUSING LID 2 11693 15 INLET OUTLET PLUG 3 11739 16 SPA TUB 1 11697 17 SPA COVER 1 11690 18 SPA COVER INFLATABLE BLADDER PRE INSTALLED IN SPA COVER 1 11689 19 GROUND CLOTH 1 11717 20 CHEMICAL DISPENSER 1 10883 21 THREE WAY TEST STRIPS 1 19635 22 WRENCH 1 11742 23 PRESSURE GAUGE 1 11741 24 SUCTION FITTING ...

Page 7: ...ndoor spa installation The room shall be properly ventilated to allow moisture to escape Install a ventilating system to prevent excess condensation moisture in the room Additional requirements for outdoor installation Spa owners may need to comply with local or states laws relating to childproof fencing safety barriers lighting and other safety requirements Contact your local building code enforc...

Page 8: ...t www intexcorp com for additional print copies Laminate the printed safety sign copy for protection from the elements Spa Control Unit Assembly 1 Connect the control panel 3 cable plug into the receptacle on top of the spa control base see drawing 1 2 Screw the control panel bolts 4 with the provided bolt wrench 6 to secure the control panel see drawing 2 3 Plug the spa control unit into a ground...

Page 9: ...Air Bladder 1 Open the inflation valve and insert the inflation hose 7 into the valve press to inflate until it is firm to the touch but not hard see drawing 7 2 Disconnect the inflation hose 7 from the air blower inflation outlet and the valve 3 Replace the control panel cap 5 back close and recess the inflation valve NOTE If there is a need to add some air to the spa tub wall or spa cover air bl...

Page 10: ...move the filter cartridge assemblies and any other spa cleaning attachment from the spa outlets before spa usage see drawing 12 Re attach them after usage for water filtration and cleaning 5 Before filling with water ensure the bottom drain valve caps are securely closed on the inside and outside 6 Fill the spa tub with freshwater to a level between MIN and MAX marked on the inside of the spa wall...

Page 11: ...ncrease or decrease The new and desired temperature setting will remain on the LED display for 5 seconds to confirm the new value NOTE The default temperature is 68 F 20 C NOTE Temperature adjustment ranges from 68 F 20 C to 104 F 40 C Reset Button Pressing the Reset button when Code E95 appears on the LED display control panel Water Filter Button This button turns the filter pump on and off The l...

Page 12: ... is below 39 F 4 C we recommend not to use the spa Press the temperature increase button to set the desired water temperature If problem persists contact Intex Service Center E95 Water temperature too high Press the temperature decrease button to lower the water temperature When the water has cooled down to 104 F 40 C press the RESET button If problem persists contact Intex Service Center E96 Syst...

Page 13: ...l 2 Change the spa water every 2 3 months or it becomes cloudy and proper water chemistry does not clear it up See Spa Tub Drainage and Spa Tub Cleaning sections for details 3 Use spa chemicals to maintain proper water chemistry Spa damage resulting from misuse of chemicals and mismanagement of spa water is not covered by the warranty 4 All occupants must shower before entering the spa Water Chemi...

Page 14: ...nsure the spa tub and spa contol unit are thoroughly dried NOTE The enclosed plugs 15 can be used to cover the water inlet and outlet connectors from the inside of the spa tub to prevent water from flowing out Spa Tub Cleaning If dirt is visible in the water or water becomes cloudy and proper water chemistry does not clear it up change the water and clean the spa tub See Spa Tub Drainage section o...

Page 15: ...in the sun for an hour before folding 4 Fold the spa tub loosely and avoid any sharp corners to prevent damage or leakage to the spa tub liner 5 Prepare additional new cartridges for next time use 6 Store the spa tub and accessories in a dry temperature controlled between 32º 104 ºF 0º 40ºC storage location 7 The original packing can be used for storage STORAGE Spa Tub and Cover Air Bladder Repair...

Page 16: ...tridge in time Increase filtration time Clean or replace the filter cartridge in time Refer to the chemical manufacture s instructions Elevate the pump with wood or another type of insulated material to bring the pump s adapters level with the spa s adapters Please check the air pressure and release air if necessary During very hot weather you must check to see whether it is necessary to release s...

Page 17: ...hall be brought before an informal dispute settlement board and unless and until the provisions of these paragraphs are carried forth no civil action may be instituted The methods and procedures of this settlement board shall be subject to the rules and regulations set forth by the Federal Trade Commission F T C IMPLIED WARRANTIES ARE LIMITED TO THE TERMS OF THIS WARRANTY AND IN NO EVENT SHALL INT...

Reviews: