Summit Series
®
II
User’s Manual
ATTENTION: N
E PAS UTILISER LE CHARGER PENDANT QUE L’EQUIPMENT EST EN MARCHE.
WARNING: LEAD-ACID BATTERIES GENERATE GASES WHICH CAN BE EXPLOSIVE. TO
PREVENT ARCING OR BURNING NEAR BATTERIES, DO NOT DISCONNECT THE CHARGER DC
OUTPUT FROM THE BATTERIES WHEN THE CHARGER IS OPERATING. KEEP SPARKS, FLAME,
AND SMOKING MATERIALS AWAY FROM BATTERIES.
WARNING: ALWAYS SHIELD EYES WHEN WORKING NEAR BATTERIES. DO NOT PUT
WRENCHES OR OTHER METAL OBJECTS ACROSS BATTERY TERMINALS OR THE BATTERY TOP.
ARCING OR EXPLOSION OF THE BATTERY CAN RESULT!
WARNING: DO NOT DISCONNECT THE CHARGER DC OUTPUT CONNECTOR FROM THE
BATTERY CONNECTOR WHILE A CHARGE CYCLE IS IN PROGRESS. THE RESULTING ARCING AND
BURNING OF THE CONNECTORS COULD CAUSE THE BATTERIES TO EXPLODE.
CAUTION: TO AVOID DAMAGE TO THE CHARGER DC CABLE AND CONNECTOR AND BATTERY
CONNECTOR, DISCONNECT BY GRASPING THE CHARGER CONNECTOR HANDLE OR BODY AND
PULLING IT STRAIGHT OUT OF THE BATTERY CONNECTOR. DO NOT PULL ON THE CHARGER
CABLE. DO NOT TWIST, ROCK, OR PULL THE CONNECTOR SIDEWAYS.
The instructions printed on the charger are for daily reference.
11.1 Off-Board Charger Operation
If the charger was configured for off-board use, follow these operating instructions:
1. With the charger DC output connector/plug disconnected from the battery connector/receptacle, connect
the charger AC power cord to an appropriate AC outlet (if not already connected) and the blue "AC
PRESENT" LED will turn on
.
2. Connect the charger DC output connector/plug to the battery connector/receptacle. The charger will start
automatically, which is indicated by the yellow "CHARGE STATUS" LED beginning to blink slowly.
3. If the charger must be disconnected from the battery while a charge cycle is in progress, first disconnect
the AC power cord from the AC outlet. Do not disconnect the charger DC output connector/plug from the
battery while a charge cycle is in progress.
4. The charge cycle 80% point is indicated by the yellow LED beginning to blink quickly.
5. The Finish charge cycle phase is indicated by the solid illumination of the yellow LED. Not all charge
profiles include a Finish phase.
6. An extended Balance/Equalize charge cycle phase is indicated by the green "CHARGE COMPLETE"
LED beginning to blink quickly. Not all charge profiles include a Balance/Equalize phase.
7. The charger automatically terminates the charge cycle when a battery reaches full charge, which is
indicated by [1] the solid illumination of the green LED or [2] the green LED beginning to blink slowly
indicating a post-charge phase. The required charge time is affected by numerous factors, including
battery amp-hour capacity, depth of discharge, battery temperature, and battery age/usage.
8. Before operating the machine/equipment, disconnect the charger DC output connector/plug from the
battery connector/receptacle by firmly grasping both connectors and pulling them straight apart.
121
Summary of Contents for eNVy neighborhood vehicle
Page 1: ...OWNER S MANUAL 1 ...
Page 58: ...Service Record Number Date Hour Meter Reading Dealer Stamp 1 2 3 4 5 6 7 8 58 ...
Page 61: ...Golf Cart Battery Install Maintenance 61 ...
Page 71: ...OCV Open Circuit Voltage vs SOC State of Charge 71 ...
Page 92: ...92 ...
Page 94: ...94 ...
Page 96: ...96 ...
Page 128: ...Summit Series II User s Manual Represented By 43068 B 128 ...