Disconnecting the charger from the battery always clears a fault. If the charger was factory-configured for on-
board use, removing AC power from the charger also clears a fault. If a fault cannot be cleared after taking
appropriate corrective action, contact your dealer for troubleshooting and/or service.
12.3 Remote LED Status and Faults
When an optional bi-color remote LED cable is attached to the external port, the LED functionality is slightly
different from the built-in LEDs and is outlined below and in the following table.
FAULT (Red) -
Indicates when a charger or battery fault has occurred. See ChargerConnect App for
fault description.
CHARGE STATUS (Amber) -
Indicates charge cycle status.
CHARGE COMPLETE (Green) -
Indicates when a charge cycle completes successfully, when an
extended Balance/Equalize charge cycle phase is active, or when a post-charge phase is active.
FAULT
(Red) LED
CHARGE
STATUS
(Amber) LED
CHARGE
COMPLETE
(Green) LED
Description
Solid On
LED check for a few seconds during charger
initialization, Solid On and then Off
Slow Blink
Bulk/Start charge cycle phase (constant power
or constant current).
Fast Blink
Absorption/Plateau charge cycle phase
(constant voltage). Greater than 80% charged.
Solid On
Finish charge cycle phase (constant current).
Not all charge profiles include a Finish phase.
Fast Blink
Balance/Equalize phase. An extended charge
cycle is occurring because a trigger condition
has been met (cycle count, etc). Not all charge
profiles include a Balance/Equalize phase.
Solid On
Charge cycle complete.
Slow Blink
Charge cycle complete. Post Charge phase
(constant voltage float, etc). Not all charge
profiles include a Post Charge phase.
Solid On
Charge has recognized a fault condition. See
ChargerConnect app for fault description.
125
Summary of Contents for eNVy neighborhood vehicle
Page 1: ...OWNER S MANUAL 1 ...
Page 58: ...Service Record Number Date Hour Meter Reading Dealer Stamp 1 2 3 4 5 6 7 8 58 ...
Page 61: ...Golf Cart Battery Install Maintenance 61 ...
Page 71: ...OCV Open Circuit Voltage vs SOC State of Charge 71 ...
Page 92: ...92 ...
Page 94: ...94 ...
Page 96: ...96 ...
Page 128: ...Summit Series II User s Manual Represented By 43068 B 128 ...