PREARRANGEMENTS FOR INSTALLATION
2.7.1
Environmental conditions of storage and operation
Unless otherwise specifically requested, the machine is supplied with blades lubricated with protective
oil. The protection has a limit lasting 30 days in environments where temperature is ranging from -
20°C to +50°C. After this period, one can find progressive forming of rust on the blades and therefore,
if the machine is not to be used for long lengths of time, it will be necessary to restore the protection
to prevent aggression from external atmospheric or chemical agents.
Upon starting working again after a long period of inactivity, lubricate the blades with oil at the first
starting, as specified in paragraph 5.2 FIRST START-UP (NO LOAD START-UP).
All intimus International GmbH shredders may work at room temperatures varying from 0°C to 50°C.
CAUTION
If ambient temperature read the indicates MAX and MIN do not touch the
machinery surfaces without protection (gloves). Burnings could be caused by this
operation!
2.7.2
Installation site
Before the machine's arrival, the user should arrange a suitable environment to receive it.
The shredder must be installed on a suitable site, such as to allow normal machine running operations
and routine maintenance (see the enclosed drawing or lay-out).
Before starting assembly operations, make sure that the flooring can sustain the shredder's weight
(see Table 3-1 – Weights) also considering the coefficient of security stated by the regulations in force.
The installation site must also foreseen:
•
Rigged anti-slip flooring without projecting bumps;
•
Adequate illumination complying with the standard in force;
•
Earthing system complying with the standard in force;
•
Electric system prearrangement complying with the standard in force;
•
Water and pneumatic preparation work (if necessary);
•
In case of special material treatment, be equipped with an air suction system (see paragraph
notes in paragraph 2.6.2 Risks in the environment where the shredder is installed.