Operation Manual 7310 EPSHP
62
9.4 Hydraulic power supply
The overflow valve was set to 110 bar and sealed.
This setting can be checked using a manometer (included in the aggregate) by connecting it
to the manometric connection.
Unauthorized change of the pressure value is unacceptable and causes the warranty
for the aggregate to be lost!
9.4.1 Working conditions of the aggregate
•
ambient temperature of the unit from 5 °C to 30 °C,
•
HV 46 hydraulic oil,
•
dust free air,
•
free air exchange for cooling,
•
the hydraulic oil temperature must not exceed the specified value by the
manufacturer of hydraulic oil,
•
the aggregate is designed to work in a closed room, shielded against environmental
influences, i.e. direct exposure to radiation solar, atmospheric precipitation,
•
use in accordance with the principles of health and safety at work and fire regulations,
•
the unit must be operated by a qualified and trained person staff
Figure 51 Oil change in in hydraulic system