Section
2
:
Installation Instructions
Version 1.0
12
Intuicom, Inc.
2.2 Sending GPS Position to the Intuicom RTK Bridge–X from the
Trimble
®
CFX/Case IH FM-750
It may be desired to send the corrected position of the receiver to the network in order to view
the position quality on the network. The RTK Bridge-X can be configured to accept a GGA
position on the serial port and use that position to send to the network. To be able to send the
GGA position from the receiver:
•
From Main screen:
o
Select “Settings”
o
Select “System”
o
Select “Advanced”
o
Select “NMEA” Output
•
This brings up the Port Parameters screen. Ensure the following settings are set:
o
NMEA: Port B
o
Baud rate: 38400
o
Data Parity: None
•
Continue by selecting the green check icon