FAULT FINDING CHECK LIST
:
Problem:
The controller light flashes.
Action:
If the lamp flashes immediately when the power is switched on and
the joystick is engaged, switch the power off, wait a few seconds,
then switch on again. Wait for two seconds before engaging the
joystick.
Problem:
The controller lamp flashes slowly while driving.
Action:
The slow flashing means that the battery charge level is low and
should be placed on charge as soon as practicable.
Problem:
The controller lamp flashes continuously and the chair will not
operate.
Action:
The continuous flashing of the lamp means there may be a major
problem. Switch the power off, disengage the wheel clutches and
seek assistance. Contact your Dealer and advise of the problem.
Problem:
The red light on the battery charger fails to illuminate when the
power is connected to it.
Action:
Check that all the leads have been properly connected and the
mains power is turned on. If this doesn’t cause the red light on the
charger to illuminate, turn the mains power off, disconnect the lead
from the mains to the battery charger. Contact your Dealer and
advise of the problem.
Problem:
The chair is difficult to steer.
Action:
First, check the tyre pressure of all the tyres. Second, check to see if
both the clutches are engaged correctly.
Note :
If you detect that there are problems with the motors, the battery charger, the
controller or damage to the power wheelchair frame, it is recommended that you
contact the nearest Authorised Service Agent or your Distributor.
If you notice any other irregular aspect of your chair or if it fails to respond after
making some of the above inspections, phone your nearest Authorised Service
Agent or Dealer for assistance. They will advise if the power wheelchair should be
returned for repairs. If the chair is to be returned, they will advise on the
availability of replacement units, and the required method of packing and shipping.
Summary of Contents for Hydra C650PW
Page 29: ...29 ...
Page 34: ...7 7 Electromagnetic Compatibility EMC 48 7 8 Contact Details 49 ...
Page 36: ...GBK80260 Issue 1 1 07 2004 2 THIS PAGE IS LEFT BLANK INTENTIONALLY ...
Page 48: ...GBK80260 Issue 1 1 07 2004 14 THIS PAGE IS LEFT BLANK INTENTIONALLY ...
Page 64: ...GBK80260 Issue 1 1 07 2004 30 THIS PAGE IS LEFT BLANK INTENTIONALLY ...
Page 66: ...GBK80260 Issue 1 1 07 2004 32 THIS PAGE IS LEFT BLANK INTENTIONALLY ...
Page 71: ...Chapter 7 Appendices 37 Dynamic SHARK Looms For DK REMA DK PMA Power Module ...
Page 84: ...Installation Manual DK PMA SHARK Power Module by GBK80262 Issue 1 June 2004 ...
Page 87: ......
Page 89: ...GBK80262 Issue 1 1 07 2004 2 THIS PAGE IS LEFT BLANK INTENTIONALLY ...
Page 91: ...GBK80262 Issue 1 1 07 2004 4 THIS PAGE IS LEFT BLANK INTENTIONALLY ...
Page 113: ...GBK80262 Issue 1 1 07 2004 26 Dynamic SHARK DK PMA Looms ...
Page 116: ...Chapter 7 Appendices 29 Dynamic SHARK Connector Kits and Adapters ...