WARNING

DO NOT use this equipment without first reading and understanding these instructions. If 
you are unable to understand the Warnings, Cautions, and Instructions, contact distributor 
before attempting to use this equipment, otherwise, injury or damage may result.

Check all parts for shipping damage and test before use. In case of damage, DO NOT use. 
Contact the distributor for further instructions.

The Flovair cushion IS NOT designed for use in the treatment of pressure sores.

Skin condition should be checked very frequently after the installation of any new cushion.

Your therapist and physician should be consulted if you have any questions regarding weight 
relief, self-examination of the skin, or individual limitations and needs.

Make sure the hook and loop fastening straps are securely attached between the seating 
surface and cushion before using.

The Flovair cushion has a weight limitation of 250 lbs for cushion widths up to and including 
20” and 350 lbs for cushion widths over 20”.

 

ACCESSORIES WARNING

Invacare products are specifically designed and manufactured for use in conjunction with 
Invacare accessories. Accessories designed by other manufacturers have not been tested by 
Invacare and are not recommended for use with Invacare products.

 

INSTALLATION WARNING

After ANY adjustments, repair or service and before use, make sure that all attaching com-
ponent parts are secure.

NOTE:

 

Fluid

 

in

 

the

 

pelvic

 

pressure

relieving

 

insert

 

may

 

have

 

a

 

tendency

 

to

 

migrate

 

downward

 

if

 

the

 

cushion

 

is

 

resting

 

or

 

stored

 

in

 

the

 

vertical

 

position.

 

If

 

this

 

is

 

the

 

case,

 

please

 

remove

 

the

 

outer/inner

 

cover

 

to

 

inspect

 

the

 

insert.

 

If

 

migration

 

has

 

occurred,

 

gently

 

knead

 

the

 

insert

 

to

 

ensure

 

a

 

uniform

 

volume

 

of

 

fluid

 

exists

 

across

 

the

 

surface.

Assembly, Installation and Operating Instructions

SAVE THESE INSTRUCTIONS

Summary of Contents for InTouch ITFG

Page 1: ...ons regarding weight relief self examination of the skin or individual limitations and needs Make sure the hook and loop fastening straps are securely attached between the seating surface and cushion...

Page 2: ...red by the user Outer Inner Covers The outer cover is made from a water resistant fabric to protect the foam The top is fabricated from a stretch fabric The bottom is fabricated from a heavyweight non...

Page 3: ...ing surface 3 Perform one of the following Hook Attachment Strips Secure the cushion to the seating surface making sure that the strips of loop on the cushion cover are securely attached to the strips...

Page 4: ...nner cover at the same time otherwise damage to the inner cover material may occur Installing the outer cover NOTE For this procedure refer to FIGURE 2 1 Position the cushion with inner cover and the...

Page 5: ...RE 3 1 Position the cushion with the pelvic support layer toward the rear of the inner cover NOTE The back surface of the cushion is marked REAR 2 Slide the cushion into the inner cover 3 Fold the top...

Page 6: ...support layer and remove from the foam Installing the pelvic support layer 1 Center the pelvic support layer on the foam so that the side straps are centered in the contours on each side of the foam...

Page 7: ...page 4 2 Remove the pelvic support layer Refer to Removing Installing the pelvic support layer on page 6 3 Remove the front legwedge from the side of the cushion thatrequiresa lowercushion tofloorheig...

Page 8: ...be returned for warranty inspection using the serial number when applicable as identification within thirty days of return authorization date DO NOT return products to our factory without our prior co...

Reviews: