Invacare® REM 550
CODE
NUMBER
FAULT
IMMEDIATE MEASURE
FURTHER HELP
4
Fault in right-hand motor.
Connection loose/defective or
motor defective.
Check connecting plugs.
•
Disconnect batteries.
1
•
Contact your dealer.
5
Fault/brake fault on left-hand
motor.
Connection
loose/defective or motor
defective.
Check connecting plugs.
•
Disconnect batteries.
1
•
Contact your dealer.
Left-hand motor disengaged (in
the case of GB motors)
Engage motor turn the remote on and off.
-
Both motors disengaged (in the
case of standard motors)
Engage motors turn the remote on and off.
-
6
Fault/brake fault on right-hand
motor.
Connection
loose/defective or motor
defective.
Check connecting plugs.
•
Disconnect batteries.
1
•
Contact your dealer.
Right-hand motor disengaged (in
the case of GB motors)
Engage motor turn the remote on and off
-
7
Discharged battery
Charge battery
•
Disconnect batteries.
1
•
Contact your dealer.
8
Battery voltage too high.
-
•
Drive slowly and try to use more
power by, for example, switching
on the lights.
•
Contact your dealer.
9 or 10
Incorrect data transmission
between modules.
-
•
Disconnect batteries.
1
•
Contact your dealer.
22