Invacare
®
- STORM
4
MAX
SERVICE MANUAL
87
•
Undo the four Allen screws (1) with a 5 mm Allen key.
•
Remove the screws together with the Nord-Lock lock washers.
•
Undo the Allen screw (4) with a 5 mm Allen key.
•
Remove the screws together with the washers.
•
Pull the motor/transmission unit (2) out of the mounting (3) in a forward direction. In doing so,
please observe the high weight of the unit.
Refitting the motor/transmission unit:
•
Replace the defective parts.
•
Refit the motor/transmission unit in reverse order.
•
To conclude, check all the mobility aid functions.