a. Apply sticky residue cleaner to the cleaning rag and wipe away all the adhesive residue.
b. Use the flat bladed scraper or the putty knife on stubborn areas, taking care not to gouge
the plastic surface.
WARNING: Do not flood the area being cleaned with a direct spray of sticky residue cleaner as
excess cleaner may damage adjacent gaskets.
3. Apply IPA cleaner solution to a new cleaning rag and thoroughly wipe down the area cleaned with
the sticky residue cleaner.
4. Allow the plastic to dry completely.
To install a new gasket
Display RFK Panel
(gasket part number MP0526):
1. Apply new gasket, starting with the horizontal
segment along the top edge of the bezel opening.
Peel off the backing paper on this segment only,
align the gasket in the gasket channel and press
into place. Take care not to stretch the gasket.
2. Peel off the backing paper on a vertical segment,
align the gasket in the channel and press into
place. The corner should be closed and the
edges touching.
3. Repeat step 6 with the other vertical channel.
4. Before removing the backing paper, check that
the two remaining segments meet successfully in
the middle. Adjust alignment of the vertical sections if necessary.
5. Peel off the remaining backing paper on the last two segments and
press into place. The corners should be closed and the edges touching.
A small witness gap is permissible at the join at the middle bottom edge.
Contactless RFK Panel (gasket part number MP0589):
1. Apply new gasket MP0525, starting with the horizontal segment along
the top edge of the bezel opening.
Peel off the backing paper from the long, narrow gasket piece on this
segment only, align the gasket in the gasket channel and press into
place. Take care not to stretch the gasket.
2. Peel off the backing paper on the right vertical segment, align the
gasket in the channel and press into place. The top corner should be
closed and the edges touching.
3. Repeat step 2 with the bottom horizontal segment.
4. Peel off the backing paper on the left vertical segment (MP0589), align
the gasket in the channel and press into place. The top & bottom
corners should be closed and the edges touching. A small witness gap
is permissible at the bottom join.