32
Document Number
DCV-00203
Date Released
Sept. 2016
Revision Number/Security level
R03 S2
Retrofit G6+InvencoLink Wayne Vista (US) Installation Guide
Note: DO NOT use the old screws from the pump door
– they are too long.
Fig. 3.9
–
Frame screwed down
10. For Narrow Frame Dispensers; re-install the Totalizer Window screw that was removed in Step 10
of the Disassembly Procedure. (Fig 3.9.1)
Fig. 3.9.1
–
Re-installing Totalizer Window Screw
11. Close and lock the RFK door to prevent it swinging during the rest of the installation process.
12. There will be an earth cable on the RFK door frame. Attach the cable to the dispenser door earth
plate. Use the screw removed in Disassembly Step 10. Take care to route the wire around the
earth plate, then tighten the screw.
CAUTION
:
Excess cabling must be organized as to not cause obstruction when opening and closing
the dispenser doors. Failure to properly restrain the wire assemblies may result in
pinching and damaging them. IT IS THE RESPONSIBILITY AND THE DISCRETION OF
THE INSTALLER TO PROVIDE AND INSTALL ANY CABLE RESTRAINTS THAT MAY
BE NECESSARY TO FACILITATE THESE GUIDELINES.
Screw retained
from Disassembly