Hardware Operations
2017-MNU-000016
2-20
2.10
System Fans
Subdividing the motherboard area and the backplane area is a metal cage that holds the
system fans. This server contains 6 system fans which are located inside the chassis. These
system fans maintain the ideal temperature for the motherboard, backplane and disk drives.
The location of system fans is shown below:
Figure 2-20 System Fan Locations
Reminder
Before you remove or install the system fan, please follow the steps below:
Step 1:
Make sure the server is not turned on or connected to the AC power. To power off
the server, see “2.1.1 Power Off”
Step 2:
Remove the rear chassis cover. To remove the rear chassis cover, see“2.2 Rear
Step 3:
Disconnect all necessary cables.