SYSTEM OVERVIEW: IV-LIGHT VENTILATION UNIT
8
iV-Light ventilation unit | Installation instructions
2
System overview: iV-Light ventilation unit
The iV-Light ventilation unit is designed to ventilate living rooms and bedrooms in single- and
multi-family houses, hotels and guest houses, rooms in public facilities and work rooms in office
buildings. It is suitable for installation in new buildings as well as for retrofitting in old buildings.
Installation is generally carried out in the exterior wall.
The ventilation unit consists of a wall sleeve in which the thermal accumulator insert is mounted.
A lockable inner cover conceals the iV-Light discreetly from the interior. The filter integrated into
the inner cover ensures that no pollen or dust from outside enters the interior. Outside, a weather
protection hood conceals the components of the ventilation unit.
The thermal accumulator insert includes a ceramic thermal accumulator and inVENTron, two
guiding vane elements and the Xenion reversible fan. The guiding vanes on both sides of the fan
serve to straighten the air flow and ensure more efficient flow through the thermal accumulator.
The unique geometry of the Xenion reversible fan effectively reduces sound transmission.
The standard length of the wall sleeve is 495 mm. For thicker walls, a wall sleeve with a length of
745 mm can be ordered. Both versions can be shortened on site.
The ventilation unit is controlled via one of the following inVENTer system controllers
1)
:
• sMove
• inVENTer Connect
2)
• MZ-Home
Components
•
Inner cover incl. ISO Coarse 60 % filter
• Thermal accumulator insert (thermal
accumulator and inVENTron)
• Wall sleeve
• External termination
•
Pollen and activated carbon filter
(optional)
• Sound and wind protection accessories
(optional)
Models
The ventilation units of the iV-Light product range differ in their external terminations. Additional
inner covers are also available. This documentation only contains information on the standard
version of the ventilation unit. For information on the variants of the external and internal
terminations, please refer to the separate installation instructions for the respective component.
• Standard variant:
iV-Light ventilation units with weather protection grille.
1)
The operating instructions for the controller are not part of this documentation.
2)
In connection with the inVENTer Connect controller platform, it is mandatory to use the Connect inner cover.
Summary of Contents for 1001-0200
Page 1: ...www inventer de Installation instructions iV Light ...
Page 37: ...37 WARRANTY AND GUARANTEE 37 iV Light ventilation unit Installation instructions NOTES ...
Page 38: ...38 WARRANTY AND GUARANTEE 38 iV Light ventilation unit Installation instructions NOTES ...
Page 39: ...39 WARRANTY AND GUARANTEE 39 iV Light ventilation unit Installation instructions NOTES ...