12
PREPARING FOR INSTALLATION
12
iV-Light ventilation unit | Installation instructions
3
Preparing for installation
3.1 Installation position
• The installation location can be derived from the position suggested by the ventilation planning.
The exact positioning of the individual devices and control units must be checked on site and, if
necessary, adjusted.
Consult the responsible planner about this!
For optimum function, it is recommended that the ventilation unit is installed at the appropriate
point in the upper wall area (e.g. 1.80 m from the upper edge of the finished floor).
• Do not place the ventilation unit near radiators, indoor air thermostats, sensitive furniture or
above pictures.
• Do not install the unit in places where direct contact with water spray is possible.
Observe the specifications of VDE 0100 when choosing the installation location.
Minimum distances of the wall opening for the ventilation unit:
• Minimum distances to components / building elements on the internal and external wall:
NOTICE: Malfunction due to incorrect positioning of the ventilation unit.
• Note insulation thickness and possibly shutters!
• Do not install near radiators!
• Observe minimum distance of 1.2 m to adjacent air openings!
Terminal component
Distance from centre of hole on the
External wall [mm]
Internal wall [mm] frontal [mm]
Light weather protection
grille
250 circumferential
–
–
Light inner cover
–
250 circumferential 300
• between two ventilation units (pair of units) operating in push-pull mode in a room
1,2 m
1,0 m
1,0 m
1,4 m
y
1,2 m – 0,75 y
1,2 m
1,0 m
1,0 m
1,4 m
y
1,2 m – 0,75 y
1,2 m
1,0 m
1,0 m
1,4 m
y
1,2 m – 0,75 y
B
A
C
Horizontal or vertical on the same wall
Installation over corner
Installation with height offset
Summary of Contents for 1001-0200
Page 1: ...www inventer de Installation instructions iV Light ...
Page 37: ...37 WARRANTY AND GUARANTEE 37 iV Light ventilation unit Installation instructions NOTES ...
Page 38: ...38 WARRANTY AND GUARANTEE 38 iV Light ventilation unit Installation instructions NOTES ...
Page 39: ...39 WARRANTY AND GUARANTEE 39 iV Light ventilation unit Installation instructions NOTES ...