28
INSTALLATION AND ASSEMBLY
aV100 extract air system – Avio N 100
•
Installation and operating instructions
5.6
Install the aV100 extract air system with aV100 weather protection hood
(standard model)
Install wall sleeve for aV100 weather protection hood
Requirements:
The power cable has been laid.
TIP
Do not insert the wall sleeve too deeply into the wall opening.
When inserting the wall sleeve, pay attention to the thickness of the plaster. Also ensure that the
fixing elements and non-return valve point towards the exterior wall.
TIP
Do not remove the thread locks on the fixing elements until after completion of the wall work to
prevent contamination of the threads.
►
Insert the wall sleeve (1) into the wall opening
(3) from the outside.
Ensure that
the fixing elements (2)
and the non-return valve (4) point towards the
outside.
Ensure that
the notch in the non-return valve
(4) is facing downwards.
Ensure that
the wall sleeve has an overhang
of 5mm on the exterior wall.
5
1
3
2
4
►
Attach the wall sleeve (6) inside and outside
with the mounting wedges (5) so that there is a
slope of 1° – 2° to the exterior wall.
►
Check the angle of the wall sleeve (6) from the
interior using a spirit level.
5
6
1 - 2°
►
Ensure the fixing elements (7) are
horizontal using a spirit level (8).
7
8