29
INSTALLATION AND ASSEMBLY
aV100 extract air system – Avio N 100
•
Installation and operating instructions
NOTE
Contamination of the non-return valve.
Incorrect functioning of the aV100 extract air system!
►
Insert styrofoam discs before foam-sealing the wall sleeve.
DANGER
Exposed electrical components.
Electric shock and injury due to live components (230V, 50Hz)!
►
Before working on electrical installations, disconnect all affected equipment from the power
supply.
Ö
Ö
The standard model wall sleeve is installed.
►
Insert the styrofoam protective discs (9) into
the wall sleeve (10) from the outside and
inside.
9
10
►
Foam-seal the gap (12) between the wall
sleeve (11) and masonry peripherally with non-
pressing 2K fitting foam (13).
11
13
12
►
Cut the 2K fitting foam (14) and protruding
mounting wedges (15) flush with the exterior
and interior wall.
Take care not to
damage the power
cable (16) in the interior wall.
►
Remove the styrofoam protective disc from the
wall sleeve on the exterior wall side.
14
15
16