5
USER AND SAFETY INSTRUCTIONS
aV100 extract air system – Avio N 100
•
Installation and operating instructions
1.2
Intended use
When installing the equipment/system, ensure compliance with the current building regulations,
fire protection regulations and accident prevention regulations of the relevant professional as
-
sociation.
Use the equipment/system only for the applications that are described in this documentation
and only in conjunction with components which have been recommended, authorised and
described by inVENTer GmbH in this documentation. Changes or modifications to the equip
-
ment/system are not permitted.
Trouble-free and safe operation of the equipment/system depends upon proper transportation,
proper storage and installation as well as careful operation and maintenance. These
instructions are part of the equipment/system and must be permanently available. Observe all
safety instructions that are contained in this document.
The aV100 extract air system is connected directly to 230 V mains.
Observe the VDE 0100 installation regulations when connecting the equipment in rooms with a
bath and/or shower. The Avio N 100 extractor fan must only be installed outside protection area
0. When laying the power cable, observe the requirements of protection class II. Do not lay the
power cable while it is live.
Before installation, if necessary perform a biocidal pretreatment/water repellent treatment of
the plaster surface around the weather protection hood/reveal grille, in order to prevent algae
accumulation on the weather protection hood and a discolouration of the façade. Consult your
building planner about this!
Install a pressure monitor in rooms with open flues. Consult your chimney sweeper and/or build
-
ing planner about this.
During the construction work, the aV100 extract air system must remain sealed against dust. It
must not be put into operation and the dust cover must not be removed until after completion of
the construction work.
1.3
Improper use
The equipment/system is not suitable for:
•
Rooms with aggressive and corrosive gases
•
Rooms with extreme dust load
•
Structural drying
Reliable operation of the fan cannot be ensured in rooms containing polluted air.
1.4
Qualified personnel
The equipment/system may only be set up and operated in conjunction with this documenta-
tion. Installation, electrical connection and commissioning of the equipment/system may only be
performed by qualified personnel.
Qualified personnel within the meaning of the safety notices in this documentation are persons
who are authorised to install, put it into operation and identify equipment, systems and circuits
in accordance with established safety procedures.