OPERATION AND SET-UP ON THE CONTROLLER
inVENTer Connect controller platform | Operating instructions
Setting the ventilation profile
Various predefined ventilation profiles are already stored in the Connect controller system. These
are pre-configured for the different ventilation zones in the usage unit and, based on a time
regime or sensor values, automatically control the ventilation system for each ventilation zone set
up. These can be adapted to individual wishes and/or circumstances at any time.
Two different types of ventilation profile are used:
•
Time-controlled profiles
•
Automatic profiles (sensor-controlled)
Time-controlled profiles
Time-controlled profiles are based on a weekly timer. The ventilation level and ventilation mode
thus depend on the day of the week and time of day. In this way, it is possible to set the time and
day at which a change of ventilation level and/or ventilation mode is to take place to the hour. The
time (7 days, 24 h each), the ventilation level (levels 1-4) and the ventilation mode (heat recovery,
unidirectional ventilation or pause) are defined for the respective profile. Sensors integrated into
the ventilation zone (e.g. CO
2
sensor) have priority over the values stored in the weekly timer.
7 time-controlled ventilation profiles are predefined and listed in a profile table (
Annex):
Automatic profiles
These automatic profiles are not based on schedules. With these, the comparison of internal
and external temperature and humidity data is used to determine the appropriate settings for the
ventilation levels and ventilation mode. Based on these parameters, the system ventilates fully
automatically and independently selects the appropriate measures.
The following automatic profiles are available:
• Cellar ventilation with heat recovery
• Cellar ventilation without heat recovery
• Summer mode
The operation of the two cellar ventilation profiles is based on dew point control.
The automatic profiles can only be activated if:
• an Outdoor humidity/temperature sensor is installed,
• the selected ventilation zone has an Indoor humidity/temperature sensor or a CO
2
sensor or a
direct controller.
If these sensors are removed or are not paired with the controller, this ventilation zone is reset to
the default ventilation profile and a notification is sent to the user.
• Living room
• Bedroom
• Children's room
• Bathroom
• Kitchen
•
Default profile
• Holiday mode