47
OPERATION AND SET-UP ON THE CONTROLLER
inVENTer Connect controller platform | Operating instructions
• FTS19-Connect Outdoor
humidity/temperature sensor
Brief overview
The reset devices must then be re-paired with the Easy Connect e16 controller to be included in
the system again (
3.3: Pairing sensors).
PUSH
The steps for resetting described below apply equally to all other components (sensors, switching
contact).
• FTS19-Connect Indoor
humidity/temperature sensor
►
Press and hold the button until the LED lights up
solid RED. (1)
►
Release the button.
The LED flashes RED for approx. 10 seconds. (2)
►
During these 10 seconds, press the button on the
• Indoor humidity/temperature sensor (on the
underside of the housing)
or
• Outdoor humidity/temperature sensor (in the
housing)
or
• CO
2
sensor
or
• Switching contact
again to confirm the reset procedure.
The LED lights up permanently RED. (3)
The complete start routine then runs as described
for commissioning.
• CS2-Connect CO
2
sensor
• SK19-Connect switching contact
The system is now ready for reconfiguration.
PUSH
PUSH
10 Sec.